Yokogawa AXFA14G/C User Manual

Page 66

Advertising
background image

IM 01E20F12-01E

9-8

9. PARAMETER LISTS

T0903-4.EPS

Index

Parameter

Valid Range

Initial Value

Description

Write

Mode

92

SWITCH_2_
VALUE_D
(DS-34)

Indicate the value of switch 2, which switches ON and OFF
depending on the digital value of the target input parameter selected
in SWITCH_2_TARGET.

0

0: not set,
set exclude 0

93

SWITCH_2_TARGET

This parameter selects the input channel used to LIMSW_2_
VALUE_D.

O/S

1: Adhesion

Warning

0: Adheshion Alarm
1: Adhesion Warning

94

SIGNAL_LOCK

This parameter executes the signal lock function: If “Lock” is
selected, this function will be started.

Auto

0: Unlock

0: Unlock
1: Lock

95

ALARM_PERFORM

This parameter masks Alarm/Warning. By setting “0” to each bit,
corresponding Alarm/Warning are cleared. When masked the
corresponding bit of DEVICE_STATUS becomes OFF and no alarm
is displayed on LCD, and also becomes out of scope of Primary
value status, ED_ERROR setting. Valid range is 0x00000000 to
0x003F003F.

O/S

0x00010033

0x00000000 to
0x003F003F

96

SIMULATE_MODE

For commissioning and test purposes the input value from sensor
value in the Transducer Block. TB can be modified when the
hardware simulation jumper is on. It means that the sensor value
and TB will be disconnected.

Auto

0: Off

0: Off
1: Volume Flow

97

SIMULATE_TYPE

Select the type of the simulated value.

Auto

0: Fixed

0: Fixed
1: 2 points
2: 3 points
3: Ramp

98

SIMULATE_
VOLUME_
FLOW
(DS-33)

Set the fixed value for simulating the volume flow value when
SIMULATE_TYPE is selected “0: Fixed”.
When SIMULATE_MODE is selected “0: Off”, SIMULATE_
VOLUME_FLOW.Value has the same value as the current value
from the sensor. (That is, the sensor value is copied to this
parameter internally at each TB execution.) And SIMULATE_
VOLUME_FLOW.Status has the same value as VOLUME_FLOW_
VALUE.Status.
When SIMULATE_TYPE is not selected “0: Fixed”, SIMULATE_
VOLUME_FLOW shows the current simulated value.

Auto

0

Value

Good

Status

Auto

Good

Status

Value

99

SIMULATE_UP_VALUE

Set the simulated upper value when SIMULATE_TYPE is selected
“1: 2 points”, “2: 3 points”, or “Ramp”.

Auto

0

Except
SIMULATE_LO_
VALUE

100

SIMULATE_LO_VALUE

Set the simulated lower value when SIMULATE_TYPE is selected
“1: 2 points”, “2: 3 points”, or “3: Ramp”.

Auto

0

Except
SIMULATE_UP_
VALUE

101

SIMULATE_TIME

Show the time to maintain a constant value when SIMULATE_TYPE
is selected “1: 2 points” or “2: 3 points”.
Show the time to maintain a constant change, when SIMULATE_
TYPE is selected “3: Ramp”.

Auto

30

Except 0

102

OPERATION_TIME

This parameter is used to display the operation time. For example,
“1D23:45” indicates an operation time of 1 day, 23 hours, and 45
minutes.

0D 00:00

0D 00:00 to
99999D 23:59

103

ALM_RECORD1

This parameter is used to display the most-recent alarm.

0

0 to 14

104

ALM_RECORD_TIME1

This parameter is used to display the operation time at which the
alarm indicated by Alm_Record1 was occurred. For example,
“1D23:45” indicates that an alarm was triggered at the operation
time of 1 day, 23 hours, and 45 minutes.

0D 00:00

0D 00:00 to
99999D 23:59

105

ALM_RECORD2

This parameter is used to display the second most recent alarm.

0

0 to 14

106

ALM_RECORD_TIME2

This parameter is used to display the operation time at which the
alarm indicated by Alm_Record2 was occurred.

0D 00:00

0D 00:00 to
99999D 23:59

107

ALM_RECORD3

This parameter is used to display the third most recent alarm.

0

0 to 14

108

ALM_RECORD_TIME3

This parameter is used to display the operation time at which the
alarm indicated by Alm_Record3 was occurred.

0D 00:00

0D 00:00 to
99999D 23:59

109

ALM_RECORD4

This parameter is used to display the fourth most recent alarm.

0

0 to 14

110

ALM_RECORD_TIME4

This parameter is used to display the operation time at which the
alarm indicated by Alm_Record4 was occurred.

0D 00:00

0D 00:00 to
99999D 23:59