9. PARAMETER LISTS

9.5

DI Block Parameter List (DI1: Slot5, DI2: Slot6)

T0905-1.EPS

Index

Parameter

Valid Range

Initial Value

Description

Write

Mode

16

BLOCK_OBJECT
(DS-32)

Information on this block such as Block Tag, DD Revision, Execution
Time etc.

17

ST_REV

The revision level of the static data associated with the function
block. The revision value will be incremented each time a static
parameter value in the block is changed.

0

18

TAG_DESC

The user description of the intended application of the block.

Auto

Space

19

STRATEGY

The strategy field can be used to identify grouping of blocks.
This data is not checked or processed by the block.

Auto

0 to 65535

0

20

ALERT_KEY

The identification number of the plant unit. This information may be
used in the host for sorting alarms, etc.

Auto

0 to 255

0

21

TARGET_MODE

Set the Target of block mode (MODE_BLK) to Auto, Man or O/S
according to the Write Mode of the parameter to be set or changed.

Auto

The permitted bit is
only available.

Auto

30

CHANNEL

Reference to the active Transducer Block which provides the
measurement value to the Function Block.

318: LIMSW_1_VALUE_D

324: LIMSW_2_VALUE_D

330: SWITCH_1_VALUE_D

332: SWITCH_2_VALUE_D

O/S

318, 324, 330, 332

DI1: 0x013E

(1, 62),

DI2: 0x0144

(1,68)

31

INVERT

Indicates whether the input value of the PV_D should be logically
inverted before it is stored in the OUT_D.

Auto

0: not inverted
1: invert

0: not inverted

36

FSAFE_TYPE

Defines reaction of device, if a fault is detected.

Auto

0: FSAFE_VAL,
1: last valid OUT

Value

2: wrong calculated

Val

1: last valid

OUT Value

37

FSAFE_VAL_D

Default value for the OUT_D parameter, if sensor or sensor
electronic fault is detected.

Auto

0

0 or 1

0: Disabled,
Enable exclude 0

40

SIMULATE
(DS-51)

41-50 reserved by PNO

51

VIEW_DI_FB

View objects allow the following groups of physical block parameter
values to be read with one read request.

ST_REV, MODE_BLK, ALARM_SUM, OUT_D

For commissioning and test purposes the input value from the
Transducer Block in the Discrete Input Function Block, DI-FB can be
modified when the hardware simulation jumper is on. That means
that the Transducer and DI-FB will be disconnected.

Auto

0

22

MODE_
BLK
(DS-37)

The mode parameter is a structured parameter composed of the
actual mode, the normal mode and the permitted mode.

Actual: Indicates the current operating condition.

Permit: Indicates the operating condition that the block is allowed

to take.

Normal: Indicates the operating condition that the block will

usually take.

Auto

23

ALARM_
SUM
(DS-42)

Current

The current alert status, unacknowledged status, unreported status
and disabled status of the alarms associated with the function block.

Bit0, Bit7 are
available.

0

Value

This parameter contains the current measurement value from
Transducer Block or configuration adjusted engineering unit and the
belonging state in AUTO MODE.
OUT contains the value and status set by an operator in MAN MODE.

Man

0

Simulate_Status

Auto

0

Simulate_Value

Auto

0: Disabled

Simulate_Value

Actual

24

BATCH
(DS-67)

25

Not used

26

OUT_D
(DS-34)

This parameter is intended to be used in Batch applications in line
with IEC 61512 .

Auto

0

BATCH_ID

Auto

0

RUP

Man

0

Status

Auto

0

OPERATION

Auto

0

PHASE

O/S bit, Man bit,
Auto bit

O/S,Man,Auto

Permitted

0

for future use

Unacknowledged

0

for future use

Unreported

0

for future use

Disabled

The permitted bit is
only available.

Auto

Normal