General specifications, 1 standard specifications, General specifications -1 – Yokogawa AXFA14G/C User Manual

Page 56: Standard specifications -1, Standard performance

Advertising
background image

IM 01E20F12-01E

8-1

8. GENERAL SPECIFICATIONS

8.

GENERAL SPECIFICATIONS

8.1

STANDARD SPECIFICATIONS

For items other than those described below,
refer to IM 01E20D01-01E, IM 01E20C02-01E.

Applicable Models:

Integral Flowmeter AXF
Remote Converter AXFA14

Output Signal:

Digital communication signal based on PROFIBUS
PA protocol.

Output data

Volumetric flow, Totalized value, Status output
(Adhesion alarm, HH/H/L/LL alarm)

Input data

Totalized value reset

Function Blocks:

One AI Function block, Three Totalizer function
blocks and Two DI function blocks are available
(Profibus Profile 3.01 Compliant)

Conditions of Communication Line:

Supply voltage from the Bus: 9 to 32 V DC
Current Draw: 15mA (maximum)

Bus Address Switch:

via Hardware Address Switch or via Software

FDE (Fault Disconnection Electronic):

0 mA

Alarm Selection Function:

These informations are indicated in DIAGNOSTICS
parameter, which can be handled during normal
operation.

(Note 1) The following functions are not supported

in the Profibus model.

-

Pulse Output

-

Multi-range Function

-

Totalization Switch

-

Alarm Output

Power Supply Voltage:

Power supply code 1:

• AC specifications

Rated power supply: 100 to 240 V AC, 50/60 Hz

• DC specifications

Rated power supply: 100 to 120 V DC

Power supply code 2:

• AC specifications

Rated power supply: 24 V AC, 50/60 Hz

• DC specifications

Rated power supply: 24 V DC

Displayed Language:

In the case of PROFIBUS PA communication type,
only English is provided.

STANDARD PERFORMANCE

Reference Conditions:

Similar to BS EN 29104 (1993); ISO9104 (1991)
• Fluid temperature: 20

°

C

±

10

°

C (+68

°

F

±

18

°

F)

• Ambient temperature: 25

°

C

±

5

°

C (+77

°

F

±

9

°

F)

• Warm-up time: 30 min
• Straight runs:

Upstream > 10

ϫ DN

Downstream > 5

ϫ DN

• Properly grounded
• Properly centered

Accuracy (at reference conditions):

PFA/Ceramics Lining;

Size mm

(in.)

V

Ͻ

0.3 (1)

Ϯ

1.0 mm/s

Ϯ

0.5 mm/s

Ϯ

0.5 mm/s

0.3

Ϲ

V

Ϲ

10

(1) (33)

V

Ͻ

0.15 (0.5)

V

Ͻ

0.15 (0.5)

0.15

Ϲ

V

Ϲ

10

(0.5) (33)

0.15

Ϲ

V

Ϲ

10

(0.5) (33)

V

Ͻ

0.15 (0.5)

0.15

Ϲ

V

Ͻ

1

(0.5) (3.3)

1

Ϲ

V

Ϲ

10

(3.3) (33)

Ϯ

0.35% of

Rate

Ϯ

0.5 mm/s

Ϯ

0.35% of

Rate

Ϯ

0.35% of

Rate

2.5 (0.1)
to
15 (0.5)

250 (10)
to
400 (16)

25 (1.0)
to
200 (8.0)

Flow

Velocity

V m/s (ft/s)

Flow Velocity

V m/s (ft/s)

Standard

Accuracy

(Calibratio

n code B)

High Grade

Accuracy

(Calibration

code C)

Ϯ

0.18% of Rate

Ϯ

0.2mm/s

Ϯ

0.2% of Rate

T02.EPS

Polyurethane Rubber /Natural Soft Rubber /
EPDM Rubber Lining;

T03.EPS

Size mm (in.)

V

Ͻ

0.3 (1.0)

Ϯ

1.0 mm/s

0.3

Ϲ

V

Ϲ

10

(1.0) (33)

Ϯ

0.35% of Rate

25 (1.0)
to
400 (16)

Flow Velocity

V m/s (ft/s)

Standard Accuracy

(Calibration code B)

Advertising
This manual is related to the following products: