Yokogawa AXFA14G/C User Manual

Page 62

Advertising
background image

IM 01E20F12-01E

9-4

9. PARAMETER LISTS

T0902-2.EPS

Index

Parameter

Valid Range

Initial Value

Description

Write

Mode

33

FSAFE_TYPE

Defines reaction of device, if a fault is detected.

Auto

0: Failsafe Value
1: Last Valid OUT

Value

2: Wrong Calculated

Value

0.0 to 50.0% of
range

1: Last Valid

OUT

Value

34

FSAFE_VALUE

Default value for the OUT parameter, if sensor or sensor electronic
fault is detected. The unit of this parameter is the same like the OUT one.

Auto

0.0

35

ALARM_HYS

Amount the PV must return within the alarm limits before the alarm
condition clears. Alarm Hysteresis is expressed as engineering units
of the PV span.

Auto

0.5% of range

max. Value

37

HI_HI_LIM

The setting for high high alarm in engineering units.

Auto

+INF

max. Value

39

HI_LIM

The setting for high alarm in engineering units.

Auto

+INF

min. Value

41

LO_LIM

The setting of the low alarm in engineering units.

Auto

-INF

min. Value

0: No alarm
Alarm active exclude 0

43

LO_LO_LIM

The setting of the low low alarm in engineering units.

Auto

-INF

46

This parameter is used in order to show the state of the upper limit of
alarms. This parameter contains the state of the upper limit of an
alarm and the related time stamp. The time stamp expresses the
time the measured variable has been equal or higher than the upper
limit of the alarm.

0

Unacknowledged

0

Alarm State

0

Time_Stamp

0

Subcode

0

Value

0: No alarm
Alarm active exclude 0

0

Alarm State

0

Time_Stamp

0

Subcode

0

Value

HI_HI_
ALM
(DS-39)

47

This parameter is used in order to show the state of the upper limit of
warnings. This parameter contains the state of the upper limit of a
warning and the related time stamp. The time stamp expresses the
time the measured variable has been equal or higher than the upper
limit of the warning.

0

Unacknowledged

HI_ALM
(DS-39)

0: No alarm
Alarm active exclude 0

0

Alarm State

0

Time_Stamp

0

Subcode

0

Value

This parameter is used in order to display the span velocity
corresponding to PV_SCALE.EU100 (EU0).

0

Unacknowledged

VELOCITY_CHECK

0: No alarm
Alarm active exclude 0

0: Disabled,
Enable exclude 0

0

Alarm State

0

Time_Stamp

0

Subcode

0

Value

49

This parameter is used in order to show the state of the lower limit of
alarms. This parameter contains the state of the lower limit of an
alarm and the related time stamp. The time stamp expresses the
time the measured variable has been equal or lower than the lower
limit of the alarm.

0

Unacknowledged

LO_LO_
ALM
(DS-39)

48

This parameter is used in order to show the state of the lower limit of
warnings. This parameter contains the state of the lower limit of a
warning and the related time stamp. The time stamp expresses the
time the measured variable has been equal or lower than the lower
limit of the warning.

LO_ALM
(DS-39)

50

For commissioning and test purposes the input value from the
Transducer Block in the Analog Input Function Block AI-FB can be
modified. That means that the Transducer and AI-FB will be
disconnected.

Auto

0

Simulate_Status

Auto

0

Simulate_Value

Auto

Auto

0: Disabled

Simulate_Enabled

SIMULATE
(DS-50)

Character

0 to 99.999

51

61

View objects allow the following groups of physical block parameter
values to be read with one read request.

ST_REV, MODE_BLK, ALARM_SUM, OUT

VIEW_ANALOG_INPUT_FB

62

If a specific unit of OUT parameter is not in the code list the user has
the possibility to write the specific text in this parameter. The unit
code is then equal “textual unit definition”.

OUT_UNIT_TEXT

52-60 reserved by PNO