2

10:00:00:05:1e:47:30:00/3 10.32.72.105 EE_STATE_ONLINE Reachable

10:00:00:05:1e:47:30:00/10 10.32.72.106 EE_STATE_ONLINE Reachable

10:00:00:05:1e:47:30:00/12 10.32.72.107 EE_STATE_ONLINE Reachable

EE Slot: 2

SP state: Online

Primary Link KeyID: 85:1c:ca:dd:fc:8c:31:fc:87:21:26:d1:24:a0:92:be

Secondary Link KeyID:98:4f:b4:98:c0:42:ab:6b:6d:65:ba:f2:fc:aa:b5:8a

No HA cluster membership

EE Attributes:

Link IP Addr : 10.32.72.76

Link GW IP Addr : 10.32.64.1

Link Net Mask : 255.255.240.0

Link MAC Addr : 00:05:1e:53:89:03

Link MTU : 1500

Link State : UP

Media Type : DISK

Rebalance Recommended: NO

System Card Label :

System Card CID :

Remote EE Reachability :

Node WWN/Slot EE IP Addr EE State IO Link State

10:00:00:05:1e:54:22:36/0 10.32.72.62 EE_STATE_ONLINE Reachable

10:00:00:05:1e:47:30:00/1 10.32.72.104 EE_STATE_ONLINE Reachable

10:00:00:05:1e:47:30:00/3 10.32.72.105 EE_STATE_ONLINE Reachable

10:00:00:05:1e:47:30:00/10 10.32.72.106 EE_STATE_ONLINE Reachable

10:00:00:05:1e:47:30:00/12 10.32.72.107 EE_STATE_ONLINE Reachable

(output truncated)

To rebalance load between tape and disk LUNS for optimal performance on slot 1:

switch:admin> cryptocfg --rebalance 1

Rebalancing the EE may cause disruption to disk I/Os.

Backup applications to tapes may need to be

restarted after rebalance.

ARE YOU SURE (yes, y, no, n): [no] yes

Operation succeeded

To disable the key vault diagnostics:

switch:admin> cryptocfg --kvdiag -disable

Key vault diagnostic periodic tests Disabled

Operation succeeded

To re-enable the key vault diagnostics after it has been disabled:

switch:admin> cryptocfg --kvdiag -enable

Key vault diagnostic periodic tests Enabled

Interval: 5 minute(s)

Test Type: (diag) key retrieval/archival readiness

Operation succeeded