Brocade Fabric OS Command Reference (Supporting Fabric OS v7.3.0) User Manual
Page 683
Fabric OS Command Reference
653
53-1003131-01
pathInfo
2
NOTES
The execution of this command is subject to Virtual Fabric or Admin Domain restrictions that may be in 
place. Refer to Chapter 1, "Using Fabric OS Commands" and Appendix A, "Command Availability" for 
details. 
OPERANDS
This command has the following operands:
dest_switch_domain
Specifies the destination switch. To obtain path info in a Layer 2 fabric, the 
destination switch can be identified by its Domain ID, by the switch WWN, or by 
the switch name. To obtain path info across remote fabrics connected through an 
FC Router, the destination switch must be identified by its Domain ID. Identifying 
the switch by name or WWN is not accepted. This operand is optional; if omitted, 
the command prompts for input interactively. 
source_port
Specifies the port whose path to the destination domain is traced, specified as the 
port index. The embedded port (-1) is the default. The embedded port can be 
selected manually by entering the value of MAX_PORT. MAX_PORT stands for 
the maximum number of ports supported by the local switch. 
dest_port
Specifies the port on the destination switch for the path being traced. This operand 
returns the state of this port. The embedded port (-1) is used by default, or if you 
specify a destination port that is not active. The destination is specified as the port 
index. 
"-r"
Displays the reverse path in addition to the forward path. This operand is optional.
-t
Displays the command output in traceroute format. When this operand is used, 
only routing information is displayed. The output includes the time it takes, in 
microseconds, to reach each hop. Basic and extended statistics are not available 
in the traceroute format. 
-sid source_pid
Specifies the source ID of the originator device in "0xDDAAPP" format, where DD 
is domain ID, AA is area ID and PP is AL_PA ID.
-did dest_pid
Specifies the destination ID of the proxy device in "0xDDAAPP" format, where DD 
is domain ID, AA is area ID and PP is AL_PA ID. You can view the proxy device 
IDs using the nsAllShow command.
--help
Displays the command usage.
When executed without operands, pathInfo runs interactively. Specifying a destination switch is required; 
the values for the source and destination ports can be -1 to indicate the embedded port. You must specify 
the source and destination PID to display the correct TI-enabled path information across the FCR. 
Reverse-path tracing is optional. In addition, this command prompts for the following parameters: 
Max hops
The maximum number of hops that the pathInfo frame is allowed to traverse; the 
default is 25.
Fabric Id
Specifies the Fabric ID. If unspecified, the value defaults to -1 (Default switch FID 
128)
Domain|Wwn|Name
Specifies the domain ID or WWN.