Brocade Fabric OS Command Reference (Supporting Fabric OS v7.3.0) User Manual

Page 713

Advertising
background image

Fabric OS Command Reference

683

53-1003131-01

perfTTmon

2

To delete the Fabric Mode Top Talker:

Switch:admin> perfttmon --del fabricmode

To display the Fabric Mode Top Talker output:

Switch:admin> perfttmon --show dom 1 pid

=========================================================

Src_PID Dst_PID MB/sec Potential E-Ports

=========================================================

0x03f600 0x011300 121.748 2/0,2/2,2/3

0x03f600 0x011300 121.748 3/14,3/15

To identify and delete a stale Top Talker for an F_Port (the F_Port belonged to a blade that has been
removed):

Switch:admin> configshow -a | grep perf

perf.ToptalkerEnabledonC2:1

perf.ttmonc.254:254|0|0|1:

Switch:admin> perfttmon --delete -sconfig

To install an ingress and an egress Top Talker monitor on the same ASIC with the -force option (in the
following example, ports 1/33 and 1/34 are on the same ASIC. The attempt to install conflicting monitors
fails unless you use the perfTTmon command with the-force option ):

switch:admin> perfttmon --add ingress 1/33

switch:admin> perfttmon --add egress 1/34

Cannot install EE/TopTalker Egress monitor because TopTalker

Ingress monitor is already present on one of the ports of this asic

switch:admin> perfttmon --add egress 1/34 -force

SEE ALSO

perfAddEEMonitor

,

perfResourceShow

Advertising