889

53-1003131-01

portShow

2

portId: 2d1c00

portIfId: 43020028

portWwn: 20:1c:00:05:33:13:2f:b3

portWwn of device(s) connected:

Distance: normal

portSpeed: 8Gbps

FEC: Inactive

LE domain: 0

FC Fastwrite: OFF

Interrupts: 0 Link_failure: 0 Frjt: 0

Unknown: 0 Loss_of_sync: 1 Fbsy: 0

Lli: 14 Loss_of_sig: 2

Proc_rqrd: 4 Protocol_err: 0

Timed_out: 0 Invalid_word: 0

Rx_flushed: 0 Invalid_crc: 0

Tx_unavail: 0 Delim_err: 0

Free_buffer: 0 Address_err: 0

Overrun: 0 Lr_in: 2

Suspended: 0 Lr_out: 0

Parity_err: 0 Ols_in: 0

2_parity_err: 0 Ols_out: 1

CMI_bus_err: 0

To display the current state of a port with encryption enabled:

switch:admin> portshow 10/44

portIndex: 348

portName: slot10port44

portHealth: No Fabric Watch License

Authentication: None

portDisableReason: None

portCFlags: 0x1

portFlags: 0x10000103 PRESENT ACTIVE E_PORT T_PORT\

T_MASTER G_PORT U_PORT ENCRYPT LOGIN

LocalSwcFlags: 0x0

portType: 24.0

portState: 1 Online

Protocol: FC

portPhys: 6 In_Sync portScn: 1 Online Trunk master port

port generation number: 44

state transition count: 12

To display the state of a VE_Port on a chassis with an FX8-24 blade:

switch:admin> portshow 7/12

portIndex: 140

portName: slot7port12

portHealth: No Fabric Watch License

Authentication: None

portDisableReason: None

portCFlags: 0x1

portFlags: 0x490b PRESENT ACTIVE VIRTUAL E_PORT \

G_PORT U_PORT LOGICAL_ONLINE LOGIN LED

portType: 12.0

portState: 1 Online

Protocol: FC