Measurement data command – GW Instek GLC-9000 User Manual User Manual
Page 137

REMOTE CONTROL
137
Measurement Data Command
MEASure:AUTO
Queries the maximum value after auto measurement.
Note: This command can only be used for automatic testing.
Query Syntax
MEASure:AUTO?
Query Return
Returns the file name and 5 values < value1>,
<value2>, < value3>, <value4>, < value5>.
<value1>
The maximum value in Amps
<value2>
Power supply polarity:
0: Positive polarity
1: Negative polarity
<value3>
Equipment status:
0: Normal conditions
1: Disconnected live line.
2: Disconnected earth line.
3: Normal neutral line connection
conditions, 110% voltage
application.
4: Negative phase, 110% voltage
application.
5: Normal live line connection
conditions. Application of voltage
from the live line.
6:Normal neutral line connection
conditions. Application of voltage
from the neutral line.
<value4>
Leakage current type:
0: AC
1: DC
2: AC+DC
3: ACpeak