Query Example

MEMory:NUMBer?
Return: 7
A total of 7 measurement records have been saved.

MEMory:IDENtity

Queries the assigned file’s name and time it was last updated.

Query Syntax

MEMory:IDENtity? <NR1>

<NR1>

Memory number, range: 1~100.

Query Return

Returns three strings <char value1>, <char value2>,
<char value3>

<char value1>

File name.

<char value2>

File number

<char value3>

Time of the last update.

Query Example

MEMory:IDENtity? 6
Return: CeL,NO-6, 2008/08/08.
Where CeL is the name of the file. 6 is the file number
and 2008/8/8 is the update time.

MEMory:MEASure

Reads saved data.

Query Syntax

MEMory:MEASure? <NR1>

<NR1>

Memory number, range 1~100.

Query Return

Returns the file name and 5 values < value1>,
<value2>, < value3>, <value4>, < value5>.

<value1>

Maximum, in Amps

<value2>

Power supply polarity:
0: Positive polarity
1: Negative polarity

<value3>

Equipment status:
0: Normal conditions
1: Disconnected live line.
2: Disconnected earth line.

Advertising