6 .10 .1 base density – KROHNE Summit 8800 Vol 2 User Manual

Page 110

Advertising
background image

110

www.krohne.com

08/2013 - MA SUMMIT 8800 Vol2 R02 en

SUMMIT 8800

STREAM CONFIGURATION

06

In case the Norsok or API formula will be used:

or

Figure 108 Meter line density, calculated

Precision

Full/ Rounded or truncated

dps

Precision decimal places

Only the parameters not greyed-out have to be filled for CTSm:
t0

Meter reference temperature

λmh

Linear expansion coefficient of the meter housing

λmr

Linear expansion coefficient of the meter rotor

Only the parameters not grayed-out have to be filled for CPSm:
p0

Meter reference pressure

Rm

Meter inner radius

e

Poisson ratio

Em

Modulus of elasticity

AT

Area of motor rotor

t

Wall thickness

6 .10 Gas base density, relative density and specific gravity

6 .10 .1 Base density

Liquid

Gas

Steam

This section defines the selection process to arrive to an “in use” value for the base density.

There are 3 selections in order of priority with each 4 choices. The SUMMIT will start to check

the first selection. If the value is valid (not in alarm) then this selection will be choosen. If not,

then the second selection will bechecked etc. The last selection is always the keypad value as

defined later, even if all other choices are none.