KROHNE Summit 8800 Vol 2 User Manual
Page 44

44
www.krohne.com
08/2013 - MA SUMMIT 8800 Vol2 R02 en
SUMMIT 8800
METERING PRINCIPLES
03
Small volume prover (tag: piston position)
• Idle
• Initialising piston
• Initialising switches
• Waiting for initialisation
• Releasing piston
• Counting pulses
• Returning piston
• Returning piston
• Generating report
B07
Run completed ok?
Check if the run is completed successfully.
B08
Check consecutive run and
repeatability
Check is done if enough consecutive runs required is
completed successfully.
Settings repeatability or uncertainty
B09
Maximum runs exceeded?
Check if maximum runs are exceeded.
B10
Too many consecutive bad
runs?
Check if too many consecutive bad runs are performed
B11
Is error recoverable?
Is error recoverable? recoverable error are:
Valve errors
Accountable alarms
B12
Sequence failed
Sequence failed.
B13
Sequence successfully
Sequence successfully.