10 .2 Modbus link to stream flow computers
In case a dedicated prover computer is connected to multiple stream flow computers, then a
pulse bus and an RS485 Modbus communications link needs to be setup, with the prover as the
master and the stream flow computers as the slave. To setup a modbus master and slave, see
volume 3.
There is a Modbus slave file included in the program files directory:
C:\Program Files (x86)\Krohne\SUMMIT 8800 Configuration\modbus
This file can be import to the Modbus slave configuration to automatically configure all neces-
sary data for the steam flow computers.
Under modbus addresses, press import and select the correct file: