6 .11 .2 tab normal and extended – KROHNE Summit 8800 Vol 2 User Manual

Page 115

Advertising
background image

115

www.krohne.com

08/2013 - MA SUMMIT 8800 Vol2 R02 en

SUMMIT 8800

STREAM CONFIGURATION

06

6 .11 .1 GPA 2145

Liquid

Gas

Steam

When GPA 2172:1996 is selected as the energy standard in Heating Valve or as Relative Density

standard in relative density, this page will be made available.

6 .11 .2 TAB Normal and extended

The normal values refer to the 22 gas components normally used in calculations. The extended

give the other 23 components that can be found in natural gas.

The following screen appears:

Figure 114 GPA 2145 normal Gas data

Enter the GPA 2145 parameter per components used:

Mr

molar mass

Gid

molar mass ratio

Hmid

ideal gross heating value mass

Hvid

ideal gross heating value volume

hmid

ideal net heating value mass

hvid

Ideal net heating value volume

bi

summation factor

For complete information of these parameters and the values refer to the standards GPA 215

and GPA 2172.

NOTE: These standards are revised on a regular basis and as such care should be chosen to

make sure the year of issue is appropriate to the desired use.