3 .10 .3 Small volume / piston provers

Small volume provers are available as compact or conventional pipe provers which use dis-

placement to measure the volume and pulse interpolation.

Figure 14 Small compact prover

3 .10 .4 Master meter

In master metering a high accuracy master is put in series with other flow meters to be tested

while in production. This method of proving is predominately used for gas applications and is

used in-line with the flow meter being proved.