ProVU4 Controller, Profiler & Recorder/Controller - Product Manual

59407, Issue 1 – March 2008

Modbus Parameters

Page 121

Command Response Data

The data contained in the Edit Response Message returned after each profile or segment
edit message is shown below. The data seen can be an error code, the number of unused
segments, the profile number following a successful profile header creation/edit.
The error code shown will be as appropriate for the request message and instrument status.

Two Byte Response

Command Response Name

Low Byte

High Byte

Description

Profile Number

A/R

A/R

The number of the profile created or edited

Segments Remaining

A/R

A/R

The number of unused segments remaining

Command Successfully

0x4F

0x4B

The command requested executed without error

Command Not Recognized

0xFF

0xFF

The command is not recognized

Profile Number Invalid

0xF0

0x00

The profile number specified is not available.

Profile Name Invalid

0xF0

0x01

The profile name/characters are not valid

Start Signal Invalid

0xF0

0x02

The start signal is not recognized

Start Time Invalid

0xF0

0x03

The specified time is not within range

Start Day Invalid

0xF0

0x04

The specified day is not recognized

Starting Setpoint Invalid

0xF0

0x05

The specified starting setpoint is not recognized

Profile Recovery Invalid

0xF0

0x06

The profile recovery is not recognized

Recovery Time Invalid

0xF0

0x07

The recovery time is not within limits

Abort Action Invalid

0xF0

0x08

The abort action is not recognized

Profile Cycles Invalid

0xF0

0x09

The number of profile cycles is not within limits

Segment Number Invalid

0xF0

0x0A

The segment number is not valid for this profile

Segment Type Invalid

0xF0

0x0B

The segment type is not recognized

Segment Info A Invalid

0xF0

0x0C

The segment information A not valid for segment
type defined

Segment Info B Invalid

0xF0

0x0D

The segment information B is not valid for the
segment type defined

Auto Hold Type Invalid

0xF0

0x0E

The auto hold type is not recognized

Auto hold Value Invalid

0xF0

0x0F

The auto hold value is not within input span

Events Value Invalid

0xF0

0x10

The events are not within range

No Segments Remaining

0xF0

0x11

There are no more segments available

Write Length Invalid

0xF0

0x12

The number of parameters to be written are invalid
for the function requested

Segment Setpoint Clamped

0xF0

0x13

The setpoint value entered was out of bounds. It
has been clamped within the units setpoint limits.

Read A Profile Header

Read A Profile Header - Request (to instrument)

Field Name

Data

Comments

(Dec)

(Hex)

Unit Address

A/R

A/R

The ID address of the instrument as
required

Function Code

23

17

Requires the multi read/write function

Read Start Address High Byte

32

20

Read Start Address Low Byte

06

06

Read Quantity Of Registers High Byte

00

00

Read Quantity Of Registers Low Byte

18

12

Write Start Address High Byte

32

20

Write Start Address Low Byte

06

06