ProVU4 Controller, Profiler & Recorder/Controller - Product Manual

59407, Issue 1 – March 2008

Field Upgrade Options

Page 19

Main Board Connectors

POWER SUPPLY

BOARD

Transformer Colour

Code

100-240V (Yellow)

24-48V(Blue)

Display Board

Connections

UNIVERSAL INPUT

BOARD

Option 3 Slot
Connector PL4B

Option Slot A
Connectors PL5, & PL6

Option 1 Slot
Connectors PL7 & PL8

PC Configurator
Socket SK1

Option 2 Slot
Connector PL4A

Option Slot B
Connectors PL2A, PL2B &
PL2C

Figure 4. Main board connectors

Removing/Replacing Option Modules

1. To remove or replace modules in Option Slots 1, 2, 3, A or B, it is necessary to detach the

Power Supply and Input boards from the front panel by lifting first the upper and then
lower mounting struts.

2. Remove or fit the modules to the connectors on the Power Supply and Input boards. The

location of the connectors is shown below. Plastic pegs prevent fitting of older non-
reinforced single relay modules – Remove the peg to fit dual relay modules

3. Assemble the Power Supply and Input boards together. Tongues on each option module

locate into a slots cut into the main boards, opposite each of the connectors. Hold the
Power and Input boards together and relocate them back on their mounting struts.

4. Remove or replace the Slot C and 4 modules as required.

5. Push the boards forward to ensure correct connection to the front Display/CPU board.

CAUTION:

Check for correct orientation of the modules and that all pins are located correctly.