Functional designations, Functional designations 19 – Badger Meter SRD/SRI Valve Positioners User Manual

Page 19

Advertising
background image

FUNCTIONAL DESIGNATIONS

1a Adapter, eg. 1/2”-14 NPT
1b Cable gland
2 Plug, interchangeable with Pos.1
3
Screw terminals

1)

(11 / 12) for input (w) or

for bus connection IEC 1158-2

3)

3a Screw terminals

1)

for additional inputs / outputs

3b Test sockets Ø 2 mm, integrated in terminal block
4 Ground connection
5 Female thread

G)

1/4 -18 NPT or output I (y1)

6 Female thread

G)

1/4 -18 NPT for air supply (s)

7 Female thread

G)

1/4 -18 NPT or output II (y2)

8 Direct attachment hole for output I (y1)
9 Feedback shaft

10 Connection manifold for attachment to stroke actuators

(not with VDI/VDE 3847 version)

11 Connection base for attachment to rotary actuators
12 Travel indicator
13 Key UP
14
Key DOWN
15
Key M (Menu)

16 Status display (1 red LED, 4 green LEDs)
16a LCD with true text in 3 different languages
19 Fixing shaft for limit switch
20 Cover with window to 12
21
Air vent, dust and water protected
22 Data label
23 Tip jacks

2)

Ø 2 mm for current measurement

24 Switch

2)

for current measurement

25 Tip jacks

2)

Ø 2 mm for communication

26 Arrow is perpendicular to shaft 9 at angle 0 degree
27 Ball valve for protection class NEMA 4X
28 High cover with built-in limit switch
29 Plug for service connector

3)

30 IrCom interface

G) With marked letter "G" in the housing the pneumatic connecting threads

are cut as G 1/4 instead of 1/4-18 NPT

1)

Alternatively Cage clamps (WAGO) instead of screw terminals

2)

Only with FoxCom version

3)

Not with FoxCom version

4)

Depending on the version, the device is equipped with or without LEDs

Functional Designations

Page 19

August 2014

POS-UM-00010-EN-03

Advertising