5 Parameters

BU 0505 GB-1013

103

P400 ... P403

P401 = 0

à 0 - 10V limited

0.0V

2.5V

5.0V

10.0V

P105

P104

P402

P403

output

frequency

setpoint

voltage

positive

P401 = 1

à 0 - 10V not limited

0.0V

2.5V

5.0V

10.0V

P105

P104

P402

P403

output

frequency

setpoint

voltage

positive

negative

Pos : 187 /Anleit ungen/5. / 6. Parametrier ung [BU 0500 / BU 0200]/ Par ameter/ P400-P499/ Paramet er P404 – Filter Anal ogeing ang [ SK 54xE] @ 0\ mod_1327681301144_388. doc x @ 9326 @ @ 1

P404

[-01]

[-02]

Analog input filter

(analog input filter) )

S

1 ... 400 ms

{ all 100 }

Adjustable digital low-pass filter for the analog signal. Interference peaks are hidden, the reaction
time is extended.

[-01] = Analog input 1: analog input 1, integrated into the FI

[-02] = Analog input 2: analog input 2, integrated into the FI

The filter time for the analog inputs of the optional external IO extension modules is set in the
parameter set for the relevant module (P161).

Pos : 193 /Anleit ungen/5. / 6. Parametrier ung [BU 0500 / BU 0200]/ Par ameter/ P400-P499/ Paramet er P410 – Mi ni malfr equenz N ebensoll werte @ 0\ mod_1327681617600_388. doc x @ 9464 @ @ 1

P410

Min. freq. a-in 1/2

(Minimum frequency a-in 1/2 (auxiliary setpoint
value))

P

-400.0 ... 400.0 Hz

{ 0.0 }

The minimum frequency that can act on the setpoint via the auxiliary setpoints.

Auxiliary setpoints are all frequencies that are additionally delivered for further functions in the FI:

Actual frequency PID

Frequency addition

Frequency subtraction

Auxiliary setpoints via BUS

Process controller

Min. frequency above analog setpoint (potentiometer)