6 operating status messages – NORD Drivesystems BU0505 User Manual

Page 155

Advertising
background image

6 Operating status messages

BU 0505 GB-1013

155

Pos : 425 /Anleit ungen/6. / 7. Mel dungen z um Betriebsz ust and [BU 0500 / BU 0200]/ St örmel dungen/ Warnung C 004 [SK 180E . .. SK 5xxE] @ 2\ mod_1347457006705_388. doc x @ 47224 @ @ 1

C004

4.1

Overcurrent measurement

"Overcurrent measurement"

Warning: pulse switch off is active

The limit for activation of pulse switch off (P537) has been
reached (only possible if P112 and P536 are switched off)

• FI is overloaded

• Drive sluggish, insufficiently sized

• Ramps (P102/P103) too steep -> Increase

ramp time

• Check motor data (P201 … P209)

• Switch off slip compensation (P212)

Pos : 426 /Anleit ungen/6. / 7. Mel dungen z um Betriebsz ust and [BU 0500 / BU 0200]/ St örmel dungen/ Warnung C 008 [SK 180E . .. SK 5xxE] @ 2\ mod_1347457201563_388. doc x @ 47249 @ @ 1

C008

8.0

Parameter loss

Warning:

One of the cyclically saved messages such

as

operating hours or

enabling time could not be

saved successfully.

The warning disappears as soon as saving can be
successfully performed.

Pos : 427 /Anleit ungen/6. / 7. Mel dungen z um Betriebsz ust and [BU 0500 / BU 0200]/ St örmel dungen/ Warnung C 012 [SK 5xxE] @ 2\ mod_1361539953134_388. doc x @ 59296 @ @ 1

C012

12.1

Motor limit

"Motor switch-off limit"

Warning: 80 % of the drive torque switch-off limit (P534 [-
01]) has been exceeded.

• Reduce load on motor

• Set higher value in (P534 [-01]).

12.2

Generator limit

"Generator switch-off limit"

Warning: 80 % of the generator switch-off limit (P534 [-02])
has been exceeded.

• Reduce load on motor

• Set higher value in (P534 [-02]).

12.5

Load limit

Warning due to overshooting or undershooting of
permissible load torques ((P525) … (P529)) for the time set
in (P528).

• Adjust load.

• Change limit values ((P525) ... (P527)).

• Increase delay time (P528).

Pos : 428 /Anleit ungen/6. / 7. Mel dungen z um Betriebsz ust and [BU 0500 / BU 0200]/ St örmel dungen/ Warnung C 025 "r es ervi ert" [SK 54xE] @ 2\ mod_1361540055949_388. doc x @ 59321 @ @ 1

C025

25.4

Reserved

Error message for POSICON

à see supplementary

instructions

Pos : 429 /Anleit ungen/6. / 7. Mel dungen z um Betriebsz ust and [BU 0500 / BU 0200]/ 6./ 6. /7.2 - Mel dungen Eins chalts perr e (Tabellenüberschrif t) @ 3\ mod_1361803467385_388. doc x @ 59922 @ 5 @ 1

Advertising