P468 speed controller with htl, P475, Delay on/off switch – NORD Drivesystems BU0505 User Manual

Page 116: P480, Function busio in bits

Advertising
background image

SK 54xE – Users Manual for Frequency Inverters

116

BU 0505 GB-1013

P468

Speed controller with HTL

(Speed controller with HTL encoder)

S

P

0 ... 1

{ 0 }

Activates speed control by the HTL encoder However, this setting is ignored of parameter P300 is
set to "ON". In this case, the TTL encoder is used for speed control.

In this way, e.g. 2 rotary encoders (a TTL encoder via P300 and an HTL encoder via P468) can
be alternately activated via the 4 parameter sets of the FI.

In order to use an HL encoder, parameters P420 [-02] and [-04] as well as P461 … P463 must be
parameterised.

0 = OFF

1 = ON

Pos : 254 /Anleit ungen/5. / 6. Parametrier ung [BU 0500 / BU 0200]/ Par ameter/ P400-P499/ Paramet er P475 – Ein- / Auss chalt verzög erung Digitalf unktion [SK 5xxE] @ 0\ mod_1328002563218_388. doc x @ 10756 @ @ 1

P475

[-01]

...

[-10]

delay on/off switch

(Digital function switch on/off delay)

S

-30,000 ... 30,000
sec

{ all 0,000 }

Adjustable switch-on/off delay for the digital inputs and the digital functions of the analog inputs.
Use as a switch-on filter or simple process control is possible.

[-01] = input function 1

[-02] = input function 2

[-03] = input function 3

[-04] = input function 4

[-05] = input function 5

[-06] = Digital input 6 (above SK 520E)

[-07] = Digital input 7 (above SK 520E)

[-08] = Digital function, analog input 1

[-09] = Digital function, analog input 2

[-10] = Digital input 8 (above SK 540E)

Positive values = switch-on delayed

Negative values = switch-off delayed

Pos : 255 /Anleit ungen/5. / 6. Parametrier ung [BU 0500 / BU 0200]/ Par ameter/ P400-P499/ Paramet er P480 – Funkti on Bus I/O I n Bits [SK 5xxE] @ 0\ mod_1328002641156_388.doc x @ 10779 @ @ 1

P480

[-01]

...

[-12]

Function BusIO In Bits

(Bus I/O In Bits function)

S

0 ... 80

{ all 0 }

The Bus I/O In Bits are perceived as digital inputs (P420). They can be set to the same functions.

In order to use this function, one of the bus setpoints (P546) must be set to >Bus I/O In Bits 0-7
<. The required function must then be assigned to the relevant bit.

With the SK 54xE in association with IO extension modules these I/O bits can also process their
input signals.

[-01] = Bus I/O In Bit 0 (or SK54xE and above: + DI1 of the second IOE)

[-02] = Bus I/O In Bit 1 (or SK54xE and above: + DI2 of the second IOE)

[-03] = Bus I/O In Bit 2 (or SK54xE and above: + DI3 of the second IOE)

[-04] = Bus I/O In Bit 3 (or SK54xE and above: + DI4 of the second IOE)

[-05] = Bus I/O In Bit 4 (or SK54xE and above: + DI1 of the first IOE)

[-06] = Bus I/O In Bit 5 (or SK54xE and above: + DI2 of the first IOE)

[-07] = Bus I/O In Bit 6 (or SK54xE and above: + DI3 of the first IOE)

[-08] = Bus I/O In Bit 7 (or SK54xE and above: + DI4 of the first IOE)

[-09] = Flag 1

[-10] = Flag 2

[-11] = Bit 8 BUS control word

[-12] = Bit 9 BUS control word

The possible functions for the Bus In Bits can be found in the table of functions for the digital
inputs. Function {14} "Remote control" is not possible.

Pos : 256 /Anleit ungen/5. / 6. Parametrier ung [BU 0500 / BU 0200]/ Par ameter/ P400-P499/ Paramet er P481 – Funkti on Bus I/O O ut Bits [ SK 5xxE] @ 0\ mod_1328002703095_388. doc x @ 10802 @ @ 1

Advertising