5 parameters, P741, Process data bus out – NORD Drivesystems BU0505 User Manual

Page 145: P742 data base version, P743 inverter type

Advertising
background image

5 Parameters

BU 0505 GB-1013

145

[-13] = setpoint value 1
[-14] = setpoint value 2
[-15] = setpoint value 3
[-16] = setpoint value 4
[-17] = setpoint value 5

Setpoint data from the master
function value (Broadcast), if
P509 = 9/10
(P510 [-02])

[-18] = PLC control word

Control word, source PLC

[-19] = setpoint value 1
[-20] = setpoint value 2
[-21] = setpoint value 3
[-22] = setpoint value 4
[-23] = setpoint value 5

Setpoint data from the PLC.

Pos : 372 /Anleit ungen/5. / 6. Parametrier ung [BU 0500 / BU 0200]/ Par ameter/ P700-P799/ Paramet er P741 – Prozes sdat en Bus Out [ SK 54xE] @ 0\ mod_1328177956772_388. doc x @ 13382 @ @ 1

P741

[-01]

...

[-23]

Process Data Bus Out

(Process data Bus Out)

S

0000 ... FFFF (hex)

This parameter provides
information about the actual
status word and the actual
values that are transferred
via the bus systems.

[-01] = Status word

Status word, source from
P509.

[-02] = Actual value 1 (P543 [-01])
[-03] = Actual value 2 (P543 [-02])
[-04] = Actual value 3 (P543 [-03])
[-05] = Actual value 4 (P543 [-04])
[-06] = Actual value 5 (P543 [-05])

[-07] = Bus I/O Out Bit (P481)

The displayed value depicts
all Bus OUT Bit sources linked
with "OR".

[-08 ] = Parameter data Out 1
[-09 ] = Parameter data Out 2
[-10 ] = Parameter data Out 3
[-11 ] = Parameter data Out 4
[-12 ] = Parameter data Out 5

Data during parameter
transfer.

[-13] = Actual value 1 master

function

[-14] = Actual value 2 master

function

[-15] = Actual value 3 master

function

[-16] = Actual value 4 master

function

[-17] = Actual value 5 master

function

Actual value of master
function P502 / P503.

[-18] = PLC status word

Status word via PLC

[-19] = Actual value 1 PLC
[-20] = Actual value 2 PLC
[-21] = Actual value 3 PLC
[-22] = Actual value 4 PLC
[-23] = Actual value 5 PLC

Actual value data via PLC

Pos : 373 /Anleit ungen/5. / 6. Parametrier ung [BU 0500 / BU 0200]/ Par ameter/ P700-P799/ Paramet er P742 – D at enbankversion @ 0\ mod_1328178021821_388.doc x @ 13405 @ @ 1

P742

Data base version

(Database version)

S

0 ... 9999

Displays the internal database version of the FI.

Pos : 374 /Anleit ungen/5. / 6. Parametrier ung [BU 0500 / BU 0200]/ Par ameter/ P700-P799/ Paramet er P743 – U mric ht ert yp @ 0\ mod_1328178080214_388.doc x @ 13428 @ @ 1

P743

Inverter type

(Inverter type)

0.00 ... 250.00

Displays the inverter power in kW, e.g. "1.50"

Þ FI with 1.5 kW nominal power.