5 Parameters

BU 0505 GB-1013

97

P331

Switchover freq. PMSM

(Switchover frequency PMSM)

S

P

1.0 ... 100.0 %

{ 15.0 }

Definition of the frequency up to which in operation without encoder the control method of a

PMSM (Permanent Magnet Synchronous Motor)

is activated according to (P330). In this case,

100 % corresponds to the nominal motor frequency from (P201).

Pos : 167 /Anleit ungen/5. / 6. Parametrier ung [BU 0500 / BU 0200]/ Par ameter/ P300-P399/ Paramet er P332 – H yst eres e U ms chaltfr equenz PM SM [ SK 54xE] @ 0\ mod_1327677923148_388. doc x @ 8957 @ @ 1

P332

Hyst. Switchover PMSM

(Switchover frequency hysteresis PMSM)

S

P

0.1 ... 25.0 %

{ 2.0 }

Difference between the switch-on and switch-off point in order to prevent oscillation on the
transition of operation without encoder into the control method specified in (P330) (and vice
versa).

Pos : 168 /Anleit ungen/5. / 6. Parametrier ung [BU 0500 / BU 0200]/ Par ameter/ P300-P399/ Paramet er P333 – Fluss-R üc kkoppl ungsf aktor PMSM [SK 54xE] @ 0\ mod_1327677965944_388.doc x @ 8980 @ @ 1

P333

Flux feedback factor PMSM

(Flux feedback factor PMSM)

S

P

0 ... 400 %

{ 100 }

- In preparation -

The parameter is significant for operation without encoders.

Pos : 169 /Anleit ungen/5. / 6. Parametrier ung [BU 0500 / BU 0200]/ Par ameter/ P300-P399/ Paramet er P334 – G eberoffs et PMSM [SK 54xE] @ 0\ mod_1327678017910_388.doc x @ 9003 @ @ 1

P334

Encoder offset PMSM

(Encoder offset PMSM)

S

-0,500 ... 0,500 rev

{ 0,000 }

Evaluation of the zero track and the Sense signal is necessary for the operation of PMSM
(Permanent Magnet Synchronous Motors). The zero impulse is then used for
synchronisation of the rotor position. The offset between the zero pulse and the actual
"zero" rotor position is set in parameter (P334) "Encoder offset". If the Sense cable (+5 V
Sense and 0 V Sense) is not connected, there is no synchronisation to the zero pulse.

Pos : 170 /Anleit ungen/5. / 6. Parametrier ung [BU 0500 / BU 0200]/ Par ameter/ P300-P399/ Paramet er P350 ff. - I nf of eld @ 2\ mod_1355738281779_388. doc x @ 52511 @ @ 1

Information

PLC parameter P350 ff.

The description of the PLC-relevant parameters above P350 can be found in the manual BU 0550.