P529 mode load control – NORD Drivesystems BU0505 User Manual

Page 126

Advertising
background image

SK 54xE – Users Manual for Frequency Inverters

126

BU 0505 GB-1013

P529

Mode Load control

(Load monitoring mode)

S

P

0 ... 3

{ 0 }

The reaction of the frequency inverter to an infringement of the defined monitoring range ((P525)
… (P527)) after the elapse of the delay time (P528) is specified by parameter (P529).

0 = Fault and warning, After the elapse of the time defined in (P528), an infringement of the

monitoring range produces a fault ("E12.5"). A warning ("C12.5") is given after the elapse
of half of this time.

1 = Warning, After the elapse of half of the time defined in (P528) and infringement of the

monitoring range produces a warning ("C12.5").

2 = Error and warning, constant travel, "Error and warning during constant travel", as for

setting "0" however monitoring is inactive during acceleration phases.

3 = Warning constant travel, "Only warning during constant travel", as for setting "1",

however monitoring is inactive during acceleration phases.