5 Parameters

BU 0505 GB-1013

131

P542

[-01]

...

[-03]

Set analog output

(Set analog output)

S

0.0 ... 10.0 V

{ all 0.0 }

[-01] = Analog output: analog output integrated into the FI

[-02] = First IOE, "External analog output of first IOE": Analog output of the first IO extension

(SK xU4-IOE)

[-03] = Second IOE, "External analog output of second IOE": Analog output of the second IO

extension (SK xU4-IOE)

This function enables the setting of the analog outputs of the FI or the connected IO extension
module (SK xU4) regardless of their actual operating statuses. To do this, the relevant output
must be set to the function "External control" (e.g.: P418 = 7).

This function can either be used manually or in combination with a bus control. The value set here
will, once confirmed, be produced at the analog output.

NOTE:

The setting is not saved in the EEPROM and is lost when the frequency inverter is
switched off!