SK 54xE – Users Manual for Frequency Inverters

86

BU 0505 GB-1013

P201

Nominal motor frequency

(Nominal motor frequency)

S

P

10.0 ... 399.9 Hz

{

***

}

The motor nominal frequency determines the V/f break point at which the FI supplies the nominal

voltage (P204) at the output.

Pos : 122 /Anleit ungen/5. / 6. Parametrier ung [BU 0500 / BU 0200]/ Par ameter/ P200-P299/ Paramet er P202 – M ot or N enndrehzahl @ 0\ mod_1327588441470_388. doc x @ 7907 @ @ 1

P202

Nominal speed

(Nominal motor speed)

S

P

150 ... 24000 rpm

{

***

}

The nominal motor speed is important for the correct calculation and control of the motor slip and
the speed display (P001 = 1).

Pos : 123 /Anleit ungen/5. / 6. Parametrier ung [BU 0500 / BU 0200]/ Par ameter/ P200-P299/ Paramet er P203 – M ot or N ennstr om @ 0\ mod_1327588500455_388.doc x @ 7930 @ @ 1

P203

Nominal current

(Nominal motor current)

S

P

0.1 ... 1000.0 A

{

***

}

The nominal motor current is a decisive parameter for the current vector control.

Pos : 124 /Anleit ungen/5. / 6. Parametrier ung [BU 0500 / BU 0200]/ Par ameter/ P200-P299/ Paramet er P204 – M ot or N enns pannung @ 0\ mod_1327588687111_388.doc x @ 7953 @ @ 1

P204

Nominal voltage

(Nominal motor voltage)

S

P

100 ... 800 V

{

***

}

The >Nominal voltage< matches the mains voltage to the motor voltage. In combination with the
nominal frequency, the voltage/frequency characteristic curve is produced.

Pos : 125 /Anleit ungen/5. / 6. Parametrier ung [BU 0500 / BU 0200]/ Par ameter/ P200-P299/ Paramet er P205 – M ot or N ennleis tung @ 0\ mod_1327588736705_388.doc x @ 7976 @ @ 1

*** These settings are dependent on the nominal power of the FI or the selection in parameter P200.