Pos : 349 /Anleit ungen/5. / 6. Parametrier ung [BU 0500 / BU 0200]/ Par ameter/ P700-P799/ Paramet er P722 – Akt uelle Spannung @ 0\ mod_1328173115169_388. doc x @ 12847 @ @ 1

P722

Current voltage

(Actual voltage)

0 ... 500 V

Displays the actual AC voltage supplied by the FI output.

Pos : 350 /Anleit ungen/5. / 6. Parametrier ung [BU 0500 / BU 0200]/ Par ameter/ P700-P799/ Paramet er P723 – Akt uelle Spannungs komponente dU @ 0\ mod_1328173153339_388. doc x @ 12870 @ @ 1

P723

Voltage -d

(Actual voltage component dU)

S

-500 ... 500 V

Displays the actual field voltage component.

Pos : 351 /Anleit ungen/5. / 6. Parametrier ung [BU 0500 / BU 0200]/ Par ameter/ P700-P799/ Paramet er P724 – Akt uelle Spannungs komponente Uq @ 0\ mod_1328173194227_388. doc x @ 12893 @ @ 1

P724

Voltage -q

(Actual voltage component Uq)

S

-500 ... 500 V

Displays the actual torque voltage component.

Pos : 352 /Anleit ungen/5. / 6. Parametrier ung [BU 0500 / BU 0200]/ Par ameter/ P700-P799/ Paramet er P725 – Akt ueller c os phi @ 0\ mod_1328173237475_388.doc x @ 12916 @ @ 1

P725

Current Cos phi

(Actual cosj)

0.00 ... 1.00

Displays the actual calculated cos

j of the drive.

Pos : 353 /Anleit ungen/5. / 6. Parametrier ung [BU 0500 / BU 0200]/ Par ameter/ P700-P799/ Paramet er P726 – Sc hei nleis tung @ 0\ mod_1328173288066_388.doc x @ 12939 @ @ 1

P726

Apparent power

(Apparent power)

0.00 ... 300.00 kVA

Displays the actual calculated apparent power. The basis for calculation are the motor data
P201...P209.

Pos : 354 /Anleit ungen/5. / 6. Parametrier ung [BU 0500 / BU 0200]/ Par ameter/ P700-P799/ Paramet er P727 – M ec hanisc he Leist ung @ 0\ mod_1328173332220_388. doc x @ 12962 @ @ 1

P727

Mechanical power

(Mechanical power)

-99.99 ... 99.99 kW

Displays the actual calculated effective power of the motor. Basis for calculation are the motor
data P201...P209.

Pos : 355 /Anleit ungen/5. / 6. Parametrier ung [BU 0500 / BU 0200]/ Par ameter/ P700-P799/ Paramet er P728 – N et zspannung @ 0\ mod_1328173378202_388. doc x @ 12985 @ @ 1

P728

Input voltage

(Mains voltage)

0 ... 1000 V

Displays the actual mains voltage at the FI input.

Pos : 356 /Anleit ungen/5. / 6. Parametrier ung [BU 0500 / BU 0200]/ Par ameter/ P700-P799/ Paramet er P729 – Dr ehmoment @ 0\ mod_1328173426559_388.doc x @ 13008 @ @ 1

P729

Torque

(Torque)

-400 ... 400 %

Displays the actual calculated torque. Basis for calculation are the motor data P201...P209.

Pos : 357 /Anleit ungen/5. / 6. Parametrier ung [BU 0500 / BU 0200]/ Par ameter/ P700-P799/ Paramet er P730 – Fel d @ 0\ mod_1328173473274_388.doc x @ 13031 @ @ 1

Advertising