Incremental encoder, Encoder counting direction, Rotary encoder function test – NORD Drivesystems BU0505 User Manual

Page 60: Incremental encoder data sheet

Advertising
background image

SK 54xE – Users Manual for Frequency Inverters

60

BU 0505 GB-1013

For longer cable lengths the cable cross-section must be selected large enough so that the voltage
drop in the cable is not too great. This particularly affects the supply cable, in which the cross-section
can be increased by connecting several conductors in parallel.

Unlike incremental encoders, for sine encoders or SIN/COS encoders the signals are not in the form
of pulses, but rather in the form of sine signals (shifted by 90°).

Note

Encoder counting direction

The counting direction of the incremental encoder must correspond to that of the motor. Therefore, depending on
the rotation direction of the encoder to the motor (possibly reversed), a negative number must be set in parameter
P301.

Note

Rotary encoder function test

The voltage difference between tracks A and B can be measured with the aid of parameter P709 [-09] and [-10]. If
the incremental encoder is rotated, the value of both tracks must jump between -0.8V and 0.8V. If the voltage only
jumps between 0 and 0.8V the relevant rack is faulty. The position can no longer be determined via the
incremental encoder. We recommend replacement of the encoder!

Pos : 80 /Anl eitungen/ Elektroni k/FU und Start er/ 2. M ont age und Ins tall ati on/ 2. 11 F arb- und Kontaktbel egung für Dr ehg eber- I nkrement algeber [ SK 5xxE] @ 1\ mod_1331216115763_388.doc x @ 17854 @ 5 @ 1

Incremental encoder

According to the resolution (pulse number), incremental encoders generate a defined number of
pulses for each rotation of the encoder shaft (Track A / Track A inverse) With this, the precise speed
of the encoder or motor can be measured by the frequency inverter. By the use of a second track (B /
B inverse) shifted by 90° (¼ period), the direction of rotation can also be determined.

The supply voltage for the encoder is 10-30V. The voltage source can be an external source or the
internal voltage (according to the frequency inverter version: 12V /15V /24V).

Function

Cable colours,

for incremental encoder

Connections for SK 53xE

Terminal block X5 or X6

10-30V supply

brown / green

42(/44 /49)

15V (/24V /12V)

0V supply

white / green

40 GND/0V

Track A

brown

51 ENC A+

Track A inverse

green

52 ENC A-

Track B

grey

53 ENC B+

Track B inverse

pink

54 ENC B-

Cable shield

connected to a large area of the frequency inverter housing or shielding angle

Table 21: Colour and contact assignments for NORD TTL incremental encoders

Note

Incremental encoder data sheet

If there are deviations from the standard equipment (Type 5820.0H40, 10-30V encoder, TTL/RS422) for the
motors, please note the accompanying data sheet or consult your supplier.

Pos : 81 /Anl eitungen/ Elektroni k/FU und Start er/ 2. M ont age und Ins tall ati on/ 2. 11 F arb- und Kontaktbel egung für Dr ehg eber- Si nus - Geber [SK 54xE] @ 1\ mod_1331216120711_388.doc x @ 17878 @ 5 @ 1

Advertising