NORD Drivesystems BU0040 User Manual

Page 23

Advertising
background image

2 Parameter Boxes

– Display and control

BU 0040 GB-0113

Subject to technical alterations

23

Parameterisation with the SimpleBox / ControlBox

The parameterisation of the frequency inverter can be performed in the various operating states. All parameters
can always be changed online. Switching to the parameter mode occurs in different ways depending upon the
operating states and the enabling source.

1. If there is no enable (if necessary, press the STOP key

) via the SimpleBox, the control terminals or a

serial interface, it is still possible to switch to the parameterisation mode directly from the operating value

display with the value keys

or

. 

P 0 _ _

...

P 7 _ _

2. If an enable is present via the control terminals or a serial interface and the frequency inverter is producing

an output frequency, it is also possible to switch to the parameterisation mode directly from the operating

value display using the value keys

or

. 

P 0 _ _

...

P 7 _ _

3. If the inverter is enabled via the ControlBox (START key

), the parameterisation mode can be accessed

by pressing the START and ENTER keys (

+

or

) simultaneously.

4. Switching back to the control mode is achieved by pressing the START key

.


The following illustration is for the SimpleBox and applies accordingly for the ControlBox.

Changing parameter values

To access the parameter section, one of the value keys,

or

must be pressed. The display changes to the

menu group display

P 0 _ _

...

P 7 _ _

. After pressing the ENTER key

or

, access to the menu group is

obtained and the required parameter can be selected with the value keys.
All parameters are arranged in order in the individual menu groups in a continuous scroll pattern. It is therefore
possible to scroll forwards and backwards within this section.
Each parameter has a parameter number 

P x x x

. The significance and description of the parameters starts in

Section 5 "Parameterisation"

OK

OK

P1

P2

NORD

DRIVESYSTEMS

OK

SK CSX-3H

Select menu group

or

display parameter value or

adopt parameter value

Select function

Next menu group or
parameter number

Value -

+

Load factory setting

Parameter set display

P set No..

P1

P2

1

Off

Off

2

On

Off

3

Off

On

4

On

On

Switch from

parameterisation to control

(with enable (START))

Value +

Previous menu group or
parameter number

Value function

One menu level back or do
not adopt changed value

Pressed simultaneously:

Switching from control to

parameterisation while the

drive is running

Switch from

parameterisation to control

(without enable (STOP))