2.2.2.9 Options


Parameter

Setting value / Description / Note

P1301

Language

Value range:
see right hand column

[ … ]

Selection of languages for operation of the ParameterBox

Available languages:

German

English

Polish

Finnish

Dutch

French

Italian

Czech

Spanish

Swedish

Danish

Russian

P1302

Operating mode

Value range:
see right hand column

[Online]

Selection of the operating mode for the NORD ParameterBox

Offline:
The ParameterBox is operated autonomously. No PC or frequency inverter is connected. The
storage objects of the ParameterBox can be parameterised and administrated.

Online:
One or more inverters are located at the interface of the ParameterBox. The frequency inverter
can be parameterised and controlled.

When changing to the “ONLINE” operating mode, a bus

scan is started automatically.

PC slave:
A PC is located at the interface of the ParameterBox. The ParameterBox can be addressed as
a slave by the NORD CON software. The storage objects log on as separate frequency
inverters

S1  USS address 1
S2  USS address 2
S3  USS address 3
S4  USS address 4
S5  USS address 5

Note: If no storage object is saved, no object can be found by NORD CON.

P1303

Automatic bus scan

On, Off

[On]

Setting the switch-on characteristics.

Off
No bus scan is carried out, the frequency inverters connected before the switch-off are
located after switching on.
If the connection configuration has been changed (e.g. a different inverter has been
connected), error 223 is generated.

On
A bus scan is automatically implemented when the ParameterBox is switched on.

P1304

Contrast

0 ... 100 %
[ 50 ]

Contrast setting of the ParameterBox display

P1305

Set password

0 ... 9999

[ 0 ]

The user can set up a password in this parameter.

If a value other than 0 has been entered in this parameter, then the settings of the ParameterBox
or the parameters of the connected frequency inverter cannot be altered.