NORD Drivesystems BU0040 User Manual

Page 34

Advertising
background image

NORDAC Control and Parameter Boxes

34

Subject to technical alterations

BU 0040 GB-0113

2.2.2.5 Description of the system parameters


The menu structure of the ParameterBox is described in Section 2.2.2 "Control" under "Menu structure of the
ParameterBox
".
The following main functions are assigned to the menu groups:

Menu group

No.

Master function

Display

(P10xx):

Selection of operating values and display layout

Parameterisation

(P11xx):

Programming of all connected inverters and storage objects

Parameter administration (P12xx):

Copying and storage of complete parameter sets from storage objects and inverters

Options

(P13xx):

Setting the ParameterBox functions and all automatic processes

2.2.2.6 Parameter display

Parameter

Setting value / Description / Note

P1001

Bus scan

Off / Start

[Off]

A bus scan is initiated with this parameter. During this process a progress indicator is shown in the
display.

After a bus scan, the display reverts to the basic menu.

Parameter P1001 is reset to “Off”.

Depending on the result of this process, the ParameterBox goes into the "ONLINE" or "OFFLINE"
operating mode.

P1002

FI selection

FI1 ... FI5

[ FI1 ]

Selection of the current item to be parameterised/controlled.

The display and further operating actions refer to the item selected. In the inverter selection list,
only those devices detected during the bus scan are shown. The actual object appears in the
status line.

Note:

If an error has occurred in a connected frequency inverter, it can be
acknowledged by selecting the frequency inverter.

P1003

Display mode

Value range:
see right hand column

[Standard]

Selection of the operating values display for the ParameterBox

Standard

Any 3 values next to each other

List

Any 3 values listed with units

Large size display 1 value (any) with unit
ControlBox

1 value without unit

PLC display

Display mode for PLC functionality

((above Version 4.3), available from about the 3rd quarter 2011)

P1004

Values for display

Value range:
see right column

[Actual frequency]

Selection of a display value for the actual value display of the ParameterBox.
The value selected is placed in the first position of an internal list for the display value and is then
also used in the “Large Display” mode.
Depending on the settings in Parameter (P1003), you can select up to 3 operating display values.
The display occurs consecutively with the value selected last being inserted into the display from
the left or from the top.