3 technical data, Warnings, Inverter control error – NORD Drivesystems BU0040 User Manual

Page 40: Error message from inverter

Advertising
background image

NORDAC Control and Parameter Boxes

40

Subject to technical alterations

BU 0040 GB-0113

Display

Error number

Fault

Text in the ParameterBox

Cause

Remedy

Warnings

240

Overwrite data?
→ Yes

No

These warnings indicate that there is a possibly significant change which
needs additional confirmation.

Once the next procedure has been selected, it must be confirmed with the
"ENTER" key.

241

Delete data?
→ Yes

No

242

Different SW version?
→ Next

Cancel

243

Different series?
→ Next

Cancel

244

Delete all data?
→ Yes

No

Inverter control error

250

This function is not enabled

The function requested is not enabled at the frequency inverter parameter
interface.

Change the value of the parameter >Interface< of the connected
inverter to the required function.
More detailed information can be obtained from the operating
instructions for the frequency inverter.

251

Control command was not successful

The control command cannot be implemented by the frequency inverter, as
a higher priority function, e.g. Quick stop or an OFF signal to the control
terminals of the frequency inverter is present.

252

Control is not possible offline

Call up of a control function in Offline mode.

Change the operating mode of the ParameterBox in the
parameter >Operating Mode< P1302 to Online and repeat the
action.

253

Error acknowledgement not successful

The acknowledgement of an error at the frequency inverter was not
successful, the error message remains in effect.

Error message from inverter

Inverter error
number

Inverter error text

A fault has occurred in the inverter with the number displayed. The inverter
error number and text are displayed.

2.3 Technical data

Name

SK TU3-PAR SK PAR-2H

SK PAR-2E

SK PAR-3H

SK PAR-3E

SK CSX-3H

SK CSX-3E SK TU3-CTR

Control voltage

4.5V

DC

… 30V

DC

Power
consumption

approx. 1.3 W approx. 1.3 W approx. 1.3 W approx. 1.3 W approx. 1.3 W approx. 1.0 W approx. 1.0 W approx. 1.0 W

Display

Plain text display

4-digit, 7-segment display

Interfaces

SPI-Bus

RS485

RS485

RS485 and

RS485

RS485

RS485

SPI-Bus

Ambient
temperature

0°C … 40°C

Protection class

IP20

IP54

1)

IP54

2)

IP54

3)

IP54

2)

IP54

3)

IP54

2)

IP20

Dimensions
(L x W x D)

(73 x 100 x 20)

mm

(90 x 145 x 27)

mm

(100 x 162 x

38) mm

(117 x 73 x 24)

mm

(128 x 83 x 32)

mm

(117 x 73 x 24)

mm

(128 x 83 x 32)

mm

(73 x 100 x 20)

mm

Weight approx.

0,2 kg

0.7 kg

0.5 kg

0.2 kg

0.6 kg

0.2 kg

0.6 kg

0,2 kg

Connection
cable length

Not possible

approx. 3m

approx. 2m

approx. 2m

Not possible

1)

with plug inserted

2)

on the front side

3)

on plug socket IP20


Advertising