3 ControlBoxes

– SK POT1-1

BU 0040 GB-0113

Subject to technical alterations

55

3.2.1.2 Control connections

Illustration of the function of the SK POT1-1 control box

Connections are made according to the following table:

Frequency inverter

series

SK 2x0E

2)

SK 2x5E

3)

SK 300E

SK 5xxE

SK 700E or

SK 750E

Interface option




SK POT1-1
Terminal - Colour

No



Terminal
(Function)

SK CU4-IOE /
SK TU4-IOE


Terminal
(Function)

SK CU2-BSC /
SK CU2-STD


Terminal
(Function)

No



Terminal
(Function)

SK CU1 BSC /
SK CU1-STD /
SK CU1-MLT

Terminal
(Function)

1 - white

44

(+24V)

SK CU4-IOE

44

(+24V)

or
SK TU4-IOE

11

(+24V)

J2:42

(+15V)

X5:42

(+15V /

+24V)

Xx.3:42

(+15V)

2 - brown

21

(DIN1)

SK CU4-IOE

C1

(DIN5 (corresponds

to DIN1 of the box))

or
SK TU4-IOE

19

(DIN5 (corresponds

to DIN1 of the box))

J2:22

(DIN2)

X5:21

(DIN1)

Xx.3:21

(DIN1)

3 - green

22

(DIN2)

SK CU4-IOE

C2

(DIN6 (corresponds

to DIN2 of the box))

or
SK TU4-IOE

25

(DIN6 (corresponds

to DIN2 of the box))

J2:23

(DIN3)

X5:22

(DIN2)

Xx.3:22

(DIN2)

4 - yellow

12

(AGND)

SK CU4-IOE

1)

13

(AIN1-)

+

12

(0V))

or
SK CU4-IOE

1)

5

(AIN1-)

+

7

(0V))

SK CU2-STD

J2.2:12

(AGND)

or
SK CU2-BSC

1)

J2.13

(AIN-)

+

J2.12

(AGND))

X4:12

(AGND)

SK CU1-MLT

X2.2:12

(AGND)

or
SK CU1-BSC / -SDT)

1)

Xx.13

(AIN1-)

+

Xx.12

(AGND))

5 - grey

14

(AIN1+)

SK CU4-IOE

14

(AIN1+)

or
SK TU4-IOE

3

(AIN1+)

J2:14

(AIN1)

X4:14

(AIN1)

Xx.2:14

(AIN1)

6 - pink

11

(+ 10V)

SK CU4-IOE

11

(+10V)

or
SK TU4-IOE

1

(+10V)

J2:11

(+10V)

X4:11

(+10V)

Xx.2:11

(+10V)

1)

On the Technology Units of the SK 2xxE and on the basic I/O of the SK 300E and the basic I/O and standard I/O of the SK 700 / SK 750E, the analog inputs are

implemented as differential inputs. In order to ensure the correct functioning of the potentiometer, the analog input "AIN-" must be connected with the analog ground.

2)

For devices with an AS interface (SK 220E and SK 230E) Analog Inputs 2 (Terminal 16), and instead of AGND (Terminal 12), Terminal 14 (GND) must be used.

In addition, the function of Analog Input 2 (P400[-02]) must be parameterised to the setting {01} = "Setpoint frequency".

3)

Connection of SK POT1-1 to an SK 2x5E can alternatively by made to an IO extension module (SK xU4-IOE) via a suitable mains unit (SK xU4-24V-

…). The

connection is made according to the following pattern.