NORDAC Control and Parameter Boxes

46

Subject to technical alterations

BU 0040 GB-0113

P1

P2

Functions

In this operating mode the functions

Parameterisation

Control

Display of operating values


are available without restriction and correspond to those of the SimpleBox SK CSX-3H/ -3E.

Connections

Connection to the vertical terminal bar is by means of a 4-
wire cable.
An integrated 270

Ω termination resistor is provided for

RS485 communication.



Settings on the frequency inverter

Name

Parameter number

Value

Notes

Control word source

P509

0

Corresponds to default value

Setpoint source(s)

P510

0

Corresponds to default value

USS Baud rate

P511

3 (38400 Baud)*

Corresponds to default value

USS address

P512

0

Corresponds to default value

* Lower baud rates can also be set, however the SK SSX-3A (temporarily) configures the frequency inverter to the setting {3} = 38400Baud, if this was parameterised to the value
<19200Baud. After the mains are switched off at the frequency inverter, the original setting is once again active.


Boot UP display

After switching on, the lettering briefly appears in the display


Operation

Control of the Simple Setpoint Box SK SSX-3A in this mode is identical to that of the SimpleBox SK CSX-3H/ -3E
(see Section 2.2).

Control commands (enable/stop/direction of rotation) and setpoints from the box are only recognised by the
frequency inverter if it has not been enabled from other sources (e.g. digital input of the FI). (Priority switching).
This also means that the drive of the source from which it was started must also be set back to Stop.

Terminal bar

a)

24V

GND/0V

44

40

73

74

24V voltage supply
from FI

b)

RS485 data cable to
frequency inverter

RS485 B (-)

RS485 A (+)

SK SSX-3A

Frequency inverter SK xxxE

44

40

73

74

V

RE

F

1

0

V

A

G

N

D

0

V

A

IN

1

+

A

IN

2

+

A

O

U

T

1

D

IG

I

N

1

D

IG

I

N

2

D

IG

I

N

3

D

IG

I

N

4

V

O

+

1

5

V

D

G

N

D

0

V

11

12

13

14

16

22

23

24

25

42

40

21

D

IG

I

N

5

1

2

3

4

RE

L

2

.2

RE

L

2

.1

RE

L

1

.2

RE

L

1

.1

C

A

N

_

H

C

A

N

_

L

C

A

N

_

G

N

D

nc

C

A

N

_

S

H

L

D

C

A

N

_

G

N

D

nc

C

A

N

_

2

4

V

CA

N

_

H

CA

N

_

L

C

A

N

_

G

N

D

nc

C

A

N

_

S

H

L

D

C

A

N

_

G

N

D

nc

C

A

N

_

2

4

V

RS

4

8

5

_

A

RS

4

8

5

_

B

G

N

D

T

X

D

RX

D

41

V

O

+

5

V

+

5

V

+

2

4

V

RJ12 socket

a), c)

Connection for 485-C mode

a) If available on the frequency inverter
b) Supply via terminal 43 or 44, according to the device 24V

DC

– Supply by separate mains unit is also possible

c) Observe correct voltage (24V

DC

), if necessary, provide the supply voltage to the SK SSX3A separately.

44

24V

DC

40

GND

73

RS485 A(+)

74

RS485 B(-)

Advertising