Danger – NORD Drivesystems BU0040 User Manual

Page 6

Advertising
background image

NORDAC Control and Parameter Boxes

6

Subject to technical alterations

BU 0040 GB-0113

1 General and safety information

DANGER!

Danger due to electricity

Installation must be carried out by qualified personnel only, paying particular attention to safety and warning
instructions (refer to the manual for the drive electronics (e.g. frequency inverter).

Insertion or removal of modules or electrical connections must only be carried out when no voltage is present.
Detailed information can be found in the relevant manual for the drive electronics.


NORD control and parameter boxes enable parameterisation, control and display of the operating parameters of
the inverter series NORD SK 200E, SK 300E, SK 500E, SK 700E, SK 750E and vector mc.

Various versions of the control and parameter boxes are available. The box to be used with a particular inverter
series can be obtained by reference to the overview tables in Sections 2.4.2, 3.1.2 and 3.2.1.

1. For service and commissioning directly on the system the handheld versions of the parameter boxes

(SK PAR-2H, SK PAR-3H and SK CSX-3H) are recommended. These handheld units can be used for
parameterisation and display.

2. The built-in versions of the parameter boxes (SK PAR-2E, SK PAR-3E and SK CSX-3E), for

installation in a control panel enable control and monitoring of up to 5 frequency inverters (SK CSX-

… 1

frequency inverters) in a control cabinet.

3. The Simple Setpoint Box SK SSX-3A is primarily intended to control SK 200E series frequency inverters

and can be sued both as a handheld unit and a wall-mounted unit.

4. The SK POT1-1 control box is a simple manual control unit for the control of NORD frequency inverters

with an enabling signal and setpoint. The control box can also be used as a wall-mounted unit.

5. The ControllBox SK TU3-CTR and the ParameterBox SK TU3-PAR are exclusively designed for use

with the SK 5xxE frequency inverter series and are plugged directly into the technology unit slot of the
frequency inverter.



The ParameterBox (SK PAR-xx or SK TU3-PAR) has a storage capacity which can store the complete data
records for up to 5 inverters.
In order to archive the data, the ParameterBox SK PAR-2x can be connected to a PC via an interface converter
(SK IC1-232/485). In order to connect the SK PAR-3H, only a common USB connection cable (USB2.0
connection cable, A-series plug to B-series plug) is required. The NORD CON software necessary for this can be
downloaded free of charge from the Getriebebau NORD internet page http://www.nord.com.

It is also possible to transfer data from the PC to the ParameterBox. For this, a previously saved or created data
set is required (see Section 2.2.2.4). This is then recognised by the NORD CON Software.