NORD Drivesystems BU0040 User Manual

Page 54

Advertising
background image

NORDAC Control and Parameter Boxes

54

Subject to technical alterations

BU 0040 GB-0113

3.2.1.1 Overview

The SK POT1-1 control box can be used with the following devices.

Frequency inverter
series

Option required

Comments*

SK 2x0E




None

DIP switch (2-pole) under central inspection window
(front side of inverter) for analog input 1 / 2to {OFF}
position.

SK 2x5E


SK CU4-IOE

DIP- switch (8-pole) on Technology UnitNo: 1, 2, 3 for
analog input 1in setting {OFF}

SK TU4-IOE

with
SK TIE4-TU-BUS

(optionally with wall-mounting kit)

DIP- switch (8-pole) on Technology UnitNo: 1, 2, 3 for
analog input 1in setting {OFF}

SK CU4-24V-


See following section (Control connections) or manual
BU0200

SK TU4-24V

with
SK TIE4-TU-NET

(optionally with wall-mounting kit)

SK 300E

SK CU2-BSC

DIP switch S1-1 (Burden resistor)
in setting {OFF} and
DIP switch S1-2 ("0-10V - Signal processing")
in setting {ON}

SK CU2-STD

DIP switch S1-1 (Burden resistorfor analog input 1)
in setting {OFF}

SK 5xxE

None

Up to size 4
DIP switch AIN1

(Burden resistorfor analog input 1)

in setting {OFF}
Above size 5
DIP switch S1 and S3 (Burden resistor foranalog input 1
and "0-10V signal processing")
to setting {OFF}

SK 700E

SK CU1-BSC

(Similar to illustration)

Set bridge between X3.2-12 and X3.2-13

SK CU1-STD

DIP- Switch (

Burden resistor, analog input

)

to setting

{OFF} and

set bridge between X1.2-12 and X1.2-13

SK CU1-MLT

(Similar to illustration)

DIP switch (Burden resistor, analog input 1)
to setting {OFF}

SK 750E




As for SK 700E

As for SK 700E

* It is assumed that the connection is made to Analog Input 1.