background image

3 ControlBoxes

– SK POT1-1

BU 0040 GB-0113

Subject to technical alterations

57

3.2.2

Parameterisation

For the functions of the control box SK POT1-1, some parameters must be changed, according to the frequency
inverter and the options.
The most important of these are listed below. For further information, please refer to the manual for the relevant
frequency inverter.

Frequency inverter

SK 2x0E

1)

SK 2x5E:

SK 300E

SK 5xxE SK

700E SK 750E

+ SK xU4-IOE

+ SK xU4-24V-

Function

Input

(Parameter)

{Function}

Enable right

DIN1 (P420[-01])

{01}

DIN5 (P480[-05])

{01}

DIN1 (P420[-01])

{01}

DIN2 (P421)

{01}

DIN1 (P420)

{01}

Enable left

DIN2 (P420[-02])

{02}

DIN6 (P480[-06])

{02}

DIN2 (P420[-02])

{02}

DIN3 (P422)

{02}

DIN2 (P421)

{02}

Analog input

AIN1 (P400[-01])

{01}

AIN1 (P400[-03])

{01}

AIN1 (P400[-07])

{01}

and
DIN3 (P420[-03])

{26}

AIN1 (P400)

{01}

AIN1 (P400)

{01}

Automatic start
(if required)

No input

(P428)

{1}

No input

(P428)

{1}

No input

(P428)

{1}

No input

(P428)

{1} or {2}

No input

(P428)

{1}

1)

For devices with an AS interface (SK 220E and SK 230E) analog input 1 is not present and therefore analog input 2 must be used.

Accordingly, parameter P400[-02] must be set to Function {01}.


3.2.3

Technical data

Name

Value

Direction selector switch

Left - OFF - Right

Potentiometer

0 … 100% (0 – 10V)

Ambient temperature

0°C … 40°C

Protection class

IP66

Dimensions (L x W x D)

(120 x 80 x 80)mm

Weight approx.

1.0 kg

Wall-mounting

possible with 4 holes at the rear

Connection cable length

approx. 3m



Advertising