NORDAC Control and Parameter Boxes

26

Subject to technical alterations

BU 0040 GB-0113

2.2.2.2 ControlBox mode


Above firmware version 3.7 a further display mode (ControlBox) can be selected. If this mode is selected by the
user, the displays for the ControlBox (LED display of active parameter set and 4-digit "7-segment display") are
shown on the screen. This mode also enables access to new parameters of an inverter, even if these parameters
have not yet been implemented in the firmware of the ParameterBox. (Example: an inverter with current firmware
version is to be parameterised with a ParameterBox with an older firmware version)


1

O

_

_

_

_

O

ONLINE

I1

P1

Ready




Information

Setpoint

The digital frequency setpoint is factory set to 0Hz. To check whether the motor is working, a frequency setpoint

must be entered with the

or

keys or a jog frequency via the respective parameter >Jog frequency< (P113).


WARNING

Danger of injury if motor starts

The motor may start immediately after pressing the START key

!



Operating display
(digit)

Parameter set display
via LED symbols,
similar to SimpleBox

(see section 4.1.2)

(siehe Kap. 4.1.2)