1 General information

BU 0040 GB-0113

Subject to technical alterations

7

1.1 Features

1.1.1

ParameterBox (SK PAR-xx and SK TU3-PAR)

Illuminated, high resolution LCD graphics screen

Central unit for up to 5 inverters interlinked via RS 485

5 complete inverter data records can be stored in the memory, loaded and processed

For use as a display for various operating parameters

Automatic inverter detection

Large-screen display of individual operating parameters

Standardisation of individual operating parameters to display specific system data

Control in various languages (see parameter (P1301))

Error message display in plain language

Direct control of an inverter possible

ControlBox function possible

only SK PAR-xx:

RS 485 communication interface (SK PAR-3H: RS 485 and RS 232)

Supply voltage 4.5VDC to 30VDC

5V (or 24 V) direct current supply from the frequency inverter can be used

SK PAR-2x: with interface converter (SK IC1-232/485) connection to a standard RS 232 PC interface;
SK PAR3H via USB interface. In this case no interface converter is required

3

Protection class IP 54. For information, see Technical Data, Section 2.3.

1.1.2

SimpleBox (SK CSX-3x und SK TU3-CTR)

4-digit, 7-segment display

For use as a display for various operating parameters

Direct control of an inverter possible

LEDs for parameter set display

Saving of a complete inverter data set (only SK TU3-CTR)

only SK CSX-xx:

5V (or 24V) direct current supply directly from the frequency inverter can be used

Protection class IP 54. For information, see Technical Data, Section 2.3.


1.1.3

SetpointBox (SK SSX-3A)

4-digit, 7-segment display

24V direct current supply direct from the frequency inverter can be used

3 operating modes with automatic detection (depending on the connection)
- RS485 in control mode

(SK 2xxE, SK 300E, SK 5xxE, SK 700E*, SK 750E*)

- IO communication in control mode

(SK 2xxE only)

- IO communication in setpoint mode

(SK 2xxE only)

Protection class IP 54

Wall-mounting possible

* only with optional RS485 interface

1.1.4

Control box (SK POT1-1)

Direction switch with "0" position for selection of the direction of rotation of the drive unit

10kOhm potentiometer for the continuous setting of setpoints between 0 and 100%

Approx. 3m long connecting cable with open ends for permanent connection to the relevant digital and
analog input terminals of the frequency inverter

The box can be wall-mounted

Protection class IP 66

3

For SK PAR-3H directly via USB port (USB2.0)