HP ProLiant DL760 Server User Manual

Page 210

Advertising
background image

Troubleshooting Information E-11

Compaq Confidential – Need to Know Required

Writer: Bryce Miller Project: Compaq ProLiant DL760 Servers User Guide Comments:

Part Number: 173744-001 File Name: o-appe Troubleshooting Information.doc Last Saved On: 1/25/01 3:06 PM

Table E-5
Are all of the System Interconnect Status LED Indicators Off?

continued

Answer

Possible Reasons

The Next Step

Yes

There is a broken connection between the
system board and power switch.

A power supply problem may exist. The
power supply may not be connected or
inserted properly, may have a damaged
connector, or it may have failed.

The power supply backplane may need to be
replaced.

There is a broken cable connection between
the system and backplane.

■

Check your power source to verify an
adequate supply of AC power.

■

Remove the power supply and check
for a damaged connector. If
connector appears okay, reinsert the
power supply, firmly and correctly.

■

Check for bent pins on all power
cables.

■

Verify the proper connection of all
power cables.

Refer to “Power Problems” and “General
Hardware Problems” in the Compaq
Servers Troubleshooting Guide
for further
options.

Advertising