Vaisala WXT520 User Manual

Page 103

Advertising
background image

Chapter 7 __________________________________________________ Getting the Data Messages

VAISALA______________________________________________________________________ 101

The structure of the pressure, temperature and humidity sensor response
message:

The structure of the precipitation sensor response message:

<cr><lf>

=

Response terminator

where
$

=

Start of the message

WI

=

Device type (WI = weather instrument)

XDR

=

Transducer measurement response identifier

C

=

Transducer id 0 type (Temperature), see the
following Transducer table

23.3

=

Transducer id 0 data (Temperature)

C

=

Transducer id 0 units (C, Temperature)

0

=

Transducer id for Temperature

C

=

Transducer id 1 type (temperature)

23.3

=

Transducer id 1 data (Tp internal temperature)

C

=

Transducer id 1 units (C, Tp internal temperature)

1

=

Transducer id for Tp internal temperature

H

=

Transducer id 0 type (Humidity)

50.1

=

Transducer id 0 data (Humidity)

P

=

Transducer id 0 units (%, Humidity)

0

=

Transducer id for Humidity

P

=

Transducer id 0 type (Pressure)

1009.1

=

Transducer id 0 data (Pressure)

H

=

Transducer id 0 units (hPa, Pressure)

0

=

Transducer id for Pressure

*

Checksum delimiter

75

=

Two-character checksum for the response

<cr><lf>

=

Response terminator

where
$

=

Start of the message

Advertising