Ascii protocol, Abbreviations and units, Table 6 – Vaisala WXT520 User Manual

Page 72

Advertising
background image

User’s Guide ______________________________________________________________________

70 __________________________________________________________________ M210906EN-C

ASCII Protocol

This section presents the data commands and data message formats for
the ASCII communication protocols.

Abbreviations and Units

For changing the units, see

Chapter 8, Sensor and Data Message

Settings, on page 107

.

Table 6

Abbreviations and Units

Abbreviation

Name

Unit

Status

1

1. The letters in the status field indicate the Unit, the # character indicates invalid data.

Sn

Wind speed minimum

m/s, km/h, mph, knots

#,M, K, S, N

Sm

Wind speed average

m/s, km/h, mph, knots

#,M, K, S, N

Sx

Wind speed maximum

m/s, km/h, mph, knots

#,M, K, S, N

Dn

Wind direction minimum deg

#, D

Dm

Wind direction average

deg

#, D

Dx

Wind direction
maximum

deg

#, D

Pa

Air pressure

hPa, Pa, bar, mmHg,
inHg

#, H, P, B, M, I

Ta

Air temperature

°C, °F

#, C, F

Tp

Internal temperature

°C, °F

#, C, F

Ua

Relative humidity

%RH

#, P

Rc

Rain accumulation

mm, in

#, M, I

Rd

Rain duration

s

#, S

Ri

Rain intensity

mm/h, in/h

#, M, I

Rp

Rain peak intensity

mm/h, in/h

#, M, I

Hc

Hail accumulation

hits/cm

2

, hits/in

2

, hits

#, M, I, H

Hd

Hail duration

s

#, S

Hi

Hail intensity

hits/cm

2

h, hits/in

2

h, hits/

h

#, M, I, H

Hp

Hail peak intensity

hits/cm

2

h, hits/in

2

h, hits/

h

#, M, I, H

Th

Heating temperature

°C, °F

#, C, F

Vh

Heating voltage

V

#, N, V, W, F

2

2. For heating # = heating option is not available (has not been ordered). N = heating option is available

but have been disabled by user or the heating temperature is over the high control limit. V = heating is
on at 50% duty cycle and the heating temperature is between the high and middle control limits. W =
heating is on at 100% duty cycle and the heating temperature is between the low and middle control
limits. F = heating is on at 50% duty cycle and the heating temperature is below the low control limit.

Vs

Supply voltage

V

V

Vr

3.5 V ref. voltage

V

V

Id

Information field

alphanumeric

Advertising