Communication setting commands, Checking the current communication settings (axu), Program, see section – Vaisala WXT520 User Manual

Page 62

Advertising
background image

User’s Guide ______________________________________________________________________

60 __________________________________________________________________ M210906EN-C

Communication Setting Commands

Checking the Current
Communication Settings (aXU)

With this command you can request the current communication settings
of WXT520.

Command format in ASCII and NMEA 0183: aXU<cr><lf>

Command format in SDI-12: aXXU!

Example response in ASCII and NMEA 0183:

aXU,A=a,M=[M],T=[T],C=[C],I=[I],B=[B],D=[D],P=[P],S=[S],
L=[L],N=[N],V=[V]<cr><lf>

Example response in SDI-12:

aXXU,A=a,M=[M],T=[T],C=[C],I=[I],B=[B],D=[D],P=[P],S=[S],
L=[L],N=[N],V=[V]<cr><lf>

NOTE

Hereafter the commands to be typed are presented in normal text while
the responses of the transmitter are presented in italic.

where
a

=

Device address, which may consist of the following
characters: 0 (default) ... 9, A ... Z, a ... z.

XU

=

Device settings command in ASCII and NMEA 0183

XXU

=

Device settings command in SDI-12

<cr><lf>

=

Command terminator in ASCII and NMEA 0183

!

=

Command terminator in SDI-12

NOTE

You can add the Id information field in the supervisor data message to
provide identifying information in addition to the transmitter address.
See section

Supervisor Message on page 123

. The information field is

set as part of the factory settings (see

General Unit Settings on page

166

). You can only modify it using the Vaisala Configuration Tool.

Advertising