Changing the settings (asu) – Vaisala WXT520 User Manual

Page 127

Advertising
background image

Chapter 8 ____________________________________________ Sensor and Data Message Settings

VAISALA______________________________________________________________________ 125

Example (ASCII and NMEA 0183, device address 0):

0SU<cr><lf>

0SU,R=11110000&11000000,I=15,S=Y,H=Y<cr><lf>

Example (SDI-12, device address 0):

0XSU!0XSU,R=11110000&11000000,I=15,S=Y,H=Y<cr><lf>

Changing the Settings (aSU)

You can change the following settings:

-

parameters included in the supervisor data message,

-

update interval,

-

error messaging on/off, and

-

heating control.

Make the desired setting with the following command. Select the
correct value/letter for the setting fields, see

Setting Fields on page 124

.

See the examples.

Command format in ASCII and NMEA 0183:

aSU,R=x,I=x,S=x,H=x<cr><lf>

Command format in SDI-12;

aXSU,R=x,I=x,S=x,H=x!

where
R, I, S, H

=

The supervisor setting fields, see

Setting Fields on

page 124

.

x

=

Value for the setting

<cr><lf>

=

Command terminator in ASCII and NMEA 0183

!

=

Command terminator in SDI-12