[R]

=

Parameter selection: This field consists of 16 bits
defining the PTU parameters included in the data
messages. The bit value 0 disables and the bit value 1
enables the parameter.

The bits 1-8 determine the
parameters included in the
message obtained with the
following commands:
-ASCII: aR2 and ar2
-NMEA 0183: $--WIQ,XDR*hh
-SDI-12: aM2, aMC2, aC, and
aCC2
-SDI-12 continuous: aR2 and
aRC2

1st bit (most left)

Pa Air pressure

2nd bit

Ta Air temperature

3rd bit

Tp Internal temperature

1

1. Tp temperature value is used in pressure calculation, it does not express the air temperature.

4th bit

Ua Air humidity

5th bit

spare

6th bit

spare

7th bit

spare

8th bit

spare

&

delimiter

The bits 9-16 determine the
PTU parameters included in
the composite data message
obtained with the following
commands:
-ASCII: aR0 and ar0
-NMEA 0183: aR0, ar0
-SDI-12: aM, aMC, aC, and aCC
-SDI-12 continuous: aR and
aRC

9th bit

Pa Air pressure

10th bit

Ta Air temperature

11th bit

Tp Internal temperature1

12th bit

Ua Air humidity

13th bit

spare

14th bit

spare

15th bit

spare

16th bit

spare

[I]

=

Update interval: 1 ... 3600 seconds

[P]

=

Pressure unit: H = hPa, P = Pascal, B = bar, M =
mmHg, I = inHg

[T]

=

Temperature unit: C = Celsius, F = Fahrenheit

<cr><lf>

=

Response terminator