Chapter 5 _______________________________________________ Wiring and Power Management

VAISALA_______________________________________________________________________ 47

Internal Wiring

The 8-pin M12 connector is wired for RS-232, SDI-12, and RS-485
modes by default. The 4-wire RS-422 requires a different internal
wiring (see also

Table 1 on page 46

). Refer to the figure below if you

need to change the wiring of the M12 connector.

0505-205

Figure 23

Internal Wiring

The RS-232 interface can be accessed through the M12 connector using
a standard PC serial port. Same applies to the SDI-12 interface, since the
Rx and Tx lines are separate at the M12 connector.

Bidirectional use of the RS-485 and RS-422 interface requires a proper
adapter module between the PC and WXT520. For testing purposes, the
inverted output of either interface (screw terminal pin #3 TX-) is
directly readable with PC's Received Data line. In this case Signal
Ground for PC serial port is taken from screw terminal pin #6 SGND
(for testing purposes pin #19 VIN- will also do).

For configuration work, the Service Port is most practical, since it has
constant and convenient line parameters: RS-232/19200, 8, N, 1. See

Chapter 6, Connection Options, on page 55

and

Figure 4 on page 21

).

NOTE

The true SDI-12 line requires that the Rx and Tx wires are joined
together (outside WXT520). See the interface diagrams in the next
section.