User’s Guide ______________________________________________________________________

108 _________________________________________________________________ M210906EN-C

The response in ASCII and NMEA 0183:

aWU,R=[R],I=[I],A=[A],G=[G],U=[U],D=[D],N=[N],F=[F]<cr>
<lf>

The response in SDI-12:

aXWU,R=[R],I=[I],A=[A],G=[G],U=[U],D=[D],N=[N],F=[F]<cr
><lf>

where [R][I][A][G][U][D][N] are the setting fields, see the following
sections.

Example (ASCII and NMEA 0183, device address 0):

0WU<cr><lf>

0WU,R=01001000&00100100,I=60,A=10,G=1,U=N,D= -
90,N=W,F=4<cr><lf>

Example (SDI-12, device address 0):

0XWU!0XWU,R=11111100&01001000,I=10,A=3,G=1,U=M,D=0,N
=W,F=4<cr><lf>

where
a

=

Device address

WU

=

Wind sensor settings command in ASCII and NMEA
0183

XWU

=

Wind sensor settings command in SDI-12

<cr><lf>

=

Command terminator in ASCII and NMEA 0183

!

=

Command terminator in SDI-12