Chapter 11 ____________________________________________________ Technical Specifications

VAISALA______________________________________________________________________ 143

Operating Conditions

Table 18

Operating Conditions

Property

Description/Value

Housing protection class

IP65 (without mounting kit)
IP66 (with mounting kit attached)

Temperature
Operation

-52 ... +60 °C (-60 ... +140 °F)

Storage

-60 ... +70 °C (-76 ... +158 °F)

Relative humidity

0 ... 100 %RH

Pressure

600 ... 1100 hPa

Wind

1

1. Due to the measurement frequency used in the sonic transducers, RF

interference in the 200-400 kHz range can disturb wind measurement.

Any temporary element or object (snow, ice, bird etc.) blocking the
measurement path between the ultrasonic transducer heads may affect the
wind measurement accuracy or even invalidate the output data.

0 ... 60 m/s

Table 19

Electromagnetic Compatibility

Applicable
Standard

Description

Level tested

Performance

1

1. A = Normal performance

B = Temporary degradation (self-recoverable)
C = Temporary degradation (operator intervention needed)
D = not recoverable

CISPR 22

Radiated emissions

30 Hz - 2 GHz

Class B

CISPR 22

Conducted emissions
DC

150 Hz - 30 MHz

Class B

IEC 61000-4-2 Electrostatic discharge 6 kV con / 8 kV air B
IEC 61000-4-3 RF field immunity

2

2. Within frequency range 600 ... 700 MHz immunity for PTU is 8 V/m

10 V/m

A

IEC 61000-4-4 Electric fast transient

2 kV

B

IEC 61000-4-5 Surge

2 kV

B

IEC 61000-4-6 Conducted RF

immunity

3 V

emf

A