General unit settings, Wind configuration settings, Table 23 – Vaisala WXT520 User Manual

Page 168: Table 24

Advertising
background image

User’s Guide ______________________________________________________________________

166 _________________________________________________________________ M210906EN-C

General Unit Settings

0XF!0XF,f=11111111&11100010,o=AAC1DB1A,c=A263,
i=HEL___,n=A3430012,2=2528,3=3512 <cr><lf>

Wind Configuration Settings

0WF!0WF,g=A,l=N,t=A,0=273.00,1=273.01,2=273.00,3=273.00,4=2
73.00,5=273.00,a=45.1,b=50.2,u=54.9,v=63.1,x=65.1,y=65.1<cr><l
f>

Table 23

General Unit Settings

Field Character

Field Name

Description

f

Factory options

Selection of parameters

o

Order code

Ordering identity as delivered
(10 characters)

c

Calibration date

Y=2003, A, B,…=2005, 2006,
1..52 = week, 1...7, weekday

i

Info

Factory signature (10
characters)

n

Device s/n

A,B,...=2005,2006..., 1..52 =
week,
1...7 = weekday , 1...9999 =
serial number

2

2.5 V reference

2500mV (default)

3

3.5 V reference

3500mV (default)

Table 24

Wind Configuration Settings

Field Character

Field Name

Description

g

Strategy A=All,

N=North, E=East,

S=South

l

Pulse length

N=Normal,auto, A=Adjusted on
half, S=Short, E=Extended,
T=Test

t

Single transducer mode

A=All, N=North, E=East,
S=South

0..5

Zero adjustment

1...655.35 us (default 273.00 us)

a,b

Detect level btw. N and E

0...100 % (default 70 %)

u,v

Detect level btw. E and S

0...100 % (default 70 %)

x,y

Detect level btw. S and N

0...100 % (default 70 %)