Inputs and outputs, Table 17, Table 17 inputs and outputs – Vaisala WXT520 User Manual

Page 144

Advertising
background image

User’s Guide ______________________________________________________________________

142 _________________________________________________________________ M210906EN-C

Inputs and Outputs

Table 17

Inputs and Outputs

Property

Description/Value

Operating voltage

5 ... 32 VDC

1

1. Below 5.3 V the measurement performance for high wind speeds may be

degraded.

Average current consumption
minimum

0.1 mA @ 12 VDC (SDI-12 standby)

typical

3 mA @ 12 VDC (with default measuring
intervals)

maximum

14 mA @ 5 VDC (with constant
measurement of all parameters)

Heating voltage

Options: DC, AC, full-wave rectified AC

typical ranges

12 VDC ± 20 %, 1.1 A max
24 VDC ± 20 %, 0.6 A max
68 V

p-p

± 20 % (AC), 0.6 A

rms

max

34 V

p

± 20 % (f/w rect. AC), 0.6 A

rms

max

absolute max

32 VDC
84 V

p-p

(AC)

42 V

p

(f/w rect. AC)

Digital outputs

SDI-12, RS-232, RS-485, RS-422

Communication protocols

SDI-12 v1.3, ASCII automatic & polled,
NMEA 0183 v3.0 with query option